• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1991 Fiscal Year Final Research Report Summary

Fabrication of a new position sensitive neutron counter and its application to the analysis of nuclear reactor dynamic characteristics

Research Project

Project/Area Number 01460264
Research Category

Grant-in-Aid for General Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field Nuclear engineering
Research InstitutionNagoya University

Principal Investigator

MORI Chizuo  Nagoya University School of Engineering Professor, 工学部, 教授 (80023068)

Co-Investigator(Kenkyū-buntansha) KIMURA Itsuro  Kyoto University School of Engineering Professor, 工学部, 教授 (40027404)
NISHINA Kojiro  Nagoya University School of Engineering Professor, 工学部, 教授 (60023222)
Project Period (FY) 1989 – 1991
KeywordsPosition sensitive counter / He-3 neutron counter / Proportional counter / Neutron flux distribution measurement / Position resolution / Position linearity / Gold wire activation method / Neutron streaming
Research Abstract

The purpose of this research is the development of a position sensitive neutron counter which is geometrically thin and long and is able to insert into a narrow space or even into water. To realize the above purpose, two preamplifiers which are needed for position sensitive counter were put at only one end of the counter by alternative-electric-currently grounding the one end of the anode wire through a high voltage capacitor.
A prototype counter was fabricated to examine the relation between the capacitance and position linearity or position resolution. Position non-linearity was only 0.2% and relative position resolution was 0.24%.
He-3 position sensitive neutron counter was fabricated with dimension of 25mm outer diameter and 1.3m length and with capacitance of 2200pF. Position resolution was 7mm and position non-linearity was 0.5%. The counter was used for the measurement of neutron flux distribution in the critical assembly of The Institute of Kyoto University Research Reactor. The measurement time was only 4-5 minutes which was very short compared with several hours for the conventional gold wire activation method. Although the results of the both methods agreed each other, in the position sensitive counter method there was a slight effect of neutron streaming through the counter. On the contrary, it was found that the measurement of neutron streaming itself could be effectively possible.

  • Research Products

    (9 results)

All Other

All Publications (9 results)

  • [Publications] A.Uritani: "Improvement of Signal Readout in Charge Division Type Position Sensitive Proportional Counter" J.Nucl.Sci.& Technol.26. 1094-1101 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] C.Mori: "Application of a Logarithmic Amplifier to a Charge-division-type Position-sensitive Proportional Counter" Nucl.Instr.& Methods. A299. 128-132 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] A.Uritani: "Development of Position Sensitive Helium-3 Proportional Counter for Thermal Neutrons with Novel Signal Readout" J.Nucl.Sci.& Technol.27. 712-717 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 瓜谷 章: "熱中性子用位置検出型比例計数管の開発" 放射線. 16(2). 80-91 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] A.Uritani: "Measurement of Neutron Flux Distribution in Critical Assembly with Position Sensitive Helium-3 Proportional Counter" J.Nucl.Sci.& Technil.28. 824-830 (1991)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] A.Uritani: "Improvement of Signal Readout in Charge Division Type Position Sensitive Proportional Counter" J. Nucl. Sci. & Technol.26(12). 1094-1101 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] C. Mori: "Application of a Logarithmic Amplifier to a Charge-division-type Position-sensitive Proportional Counter" Nucl. Instr. & Methods. A299. 128-132 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] A. Uritani: "Development of Position Sensitive Helium-3 Proportional Counter for Thermal Neutrons with Novel Signal Readout" J. Nucl. Sci. & Technol.27(8). 712-717 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] A. Uritani: "Measurement of Neutron Flux Distribution in Critical Assembly with Position-Sensitive Helium-3 Proportional Counter" J. Nucl. Sci. & Technol.28(9). 824-830 (1991)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1994-03-18  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI