• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1990 Fiscal Year Final Research Report Summary

Study of Denture Foundation with B-mode Ultrasonic Equipment - Development Measuring System for Occlusal Load and Thickness of Denture Foundation -

Research Project

Project/Area Number 01571059
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 補綴理工系歯学
Research InstitutionTokyo Medical and Dental University

Principal Investigator

KOBAYASHI Ken'ichi  Tokyo Med. and Dent. Univ., Faculty of Dentistry, Lecturer, 歯学部, 講師 (00170316)

Co-Investigator(Kenkyū-buntansha) KATOH Tsuguhisa  Tokyo Med. and Dent. Univ., Faculty of Dentistry, Research Associate, 歯学部, 助手 (70095107)
Project Period (FY) 1989 – 1990
KeywordsComplete Denture / Ultrasonic Diagnosis / Image Processing / B-mode / Occlusal Force
Research Abstract

The purpose of this study was to develop the image processing system, which allows to measure the thickness of the denture foundation and the occlusal force. Using this system, we investigated the compressibility of the denture foundation and to determine the amount of relief in thickness over the specific area.
In this report, the mucosal thickness of 60 complete denture wearers were measured with 20 MHz B-Mode Ultrasonic Diagnostic Equipment, under both non occlusal load and maximum occlusal force. Moreover, the mucosal thickness of 15 complete denture wearers whose dentures were relieved by 0.25, 0.50, 0.75, 1.00mm over the areas of incisive papilla, torus palatinus and median palatine suture were also measured by the same manner.
The main results were as follows :
1. The thickness of the denture foundation could be measured at the accuracy of 0.1mm in the system.
2. Decrease in the mucosal thickness under maximum occlusal force was about 0.3mm in averages.
3. Decreasing rate in the mucosal thickness under maximum occlsal force was greater in a mandible than in a maxilla.
4. Judging from the decrease in the mucosal thickness by relief procedures, it was found that 0.50mm relief in thickness was necessary in a case of severe torus palatinus and 0.20-0.50mm relief in a moderate one.
5. Even in a case without the existence of torus palatinus, about 0.25mm relief in thickness was desirable over the incisive papilla and median palatine suture areas.

  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] H.Uchida, K.Kobayashi and M.Nagao: "Thickness Measurement of Masticatory of Masticatory Mucosa with BーMode Ultrasonic Equipment." J dent Res. 68. 677 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 石鍋 聡 小林 賢一 内田 博之 長尾 正憲: "義歯床支持粘膜の荷重による厚さの変化に関する研究" 日本補綴歯科学会雑誌. 33. 31 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 石鍋 聡: "荷重時における義歯床下粘膜の厚さの変化に関する研究" 日本補綴歯科学会雑誌. 35. 111-124 (1991)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] H. Uchida, K. Kobayashi and M. Nagao: "Thickness Measurement of Masticatory of Masticatory Mucosa with B-Mode Ultrasonic Equipment" J dent Res. 68. 677 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] S. Ishinabe, K. Kobayashi, H. Uchida and M. Nagao: "Changes of the Mucosal Thickness beneath the Denture by Occlusal Load" J Jpn Prosthodont Soc.33. 31 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] S. Ishinabe: "Mucosal Thickness of the Denture Foundation under Occlusal Force" J Jpn Prosthodont Soc.35. 111-124 (1991)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1993-08-12  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi