Development of Magnetic Field Imaging System Using CT Technique.

Research Project

Project/Area Number 01850092
Research Category

Grant-in-Aid for Developmental Scientific Research (B).

Allocation TypeSingle-year Grants
Research Field 計測・制御工学
Research InstitutionKeio University

Principal Investigator

NAKAJIMA Masato  Keio University, Faculty of Science and Technology, Professor, 理工学部, 教授 (20051766)

Co-Investigator(Kenkyū-buntansha) IKEDA Hiroyuki  Fujitsu Limited, Image Equipment Engineering Department, Manager, 情報機器事業部, 部長
MOROZUMI Tatsuru  Takushoku University, Faculty of Technology, Associate, 工学部, 助手 (50200465)
OGAWA Kouichi  Keio University, School of Medicine, Associate, 医学部, 助手 (00158817)
YUTA Shin'ichi  University of Tsukuba, Inst. of Info. Sci. and Electronics, Associate Professor, 電子情報工学系, 助教授 (00092502)
Project Period (FY) 1989 – 1990
KeywordsMagnetic Field Measurement / Tomography / CT / Electromagnetic Induction
Research Abstract

The purpose of this study is to develop the magnetic field imaging system which applies CT technique to the electromagnetic induction measurement.
In 1989. The basic experiment was performed for deciding the specifications of the developed system, and then, the magnetic field imaging system was produced according to the specification. In this system, the diameter of the reconstructed region is 10cm and the spatial resolution is 0.5mm.
In 1990, the efficacy of the developed system was confirmed by the experiment performed using the system. In the experiment, the magnetic fields leaking from permanent magnets were imaged and the distribution of the magnetic flux density and the magnetic potential were reconstructed. It took 2 minutes to collect whole projection data which was required for image reconstruction, and 20 minutes to calculate the reconstruction using 16 bit personal computer. In case that the spatial resolution is set to 2mm, only 3 minutes were required for both collecting the projection data and calculating the reconstruction. Next, the quantitative accuracy of the reconstructed image obtained by the developed system was demonstrated. The comparison of the reconstructed image to the measurement using a gauss meter, which is a conventional tool for magnetic field measurement, shows that the both measurements were almost same.
Consequently, the efficacy of the magnetic field imaging system developed in the research confirmed. However, there are some problems for the practical use of the system. It is impossible to image the magneic field surrounded by some object, since the projections in the range of 360^゚ are required. It is also impossible to image the magnetic field distributing wider than the reconstructed region. The problems will be solved in the future research.

  • Research Products

    (9 results)

All Other

All Publications (9 results)

  • [Publications] 斎藤 英雄: "CT手法による磁界の映像化ーベクトル量としての再構成ー" 電子情報通信学会論文誌DII. J 72 D II. 1839-1847 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Hideo Saito: "Reconstruction of Magnetic Flux Density as Vector Quantity by CT Technique" IEEE Transactions on Instrumentation and Measurement. 38,2. 415-420 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 斎藤 英雄: "CT手法による磁界の映像化システム" センサ技術. 10,2. 17-21 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Hideo Saito: "High Speed Data Collection System for Magnetic Field Imaging by CT Technique" IEEE Transactions on Instrumentation and Measurement. 39,5. 739-744 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 斎藤 英雄: "CT手法による磁界の映像化ー回転走査方式による投影デ-タ収集法ー" 電子情報通信学会論文誌DII. J74DII. 282-284 (1991)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Hideo Saito et. al.,: "Magnetic Field Imaging by CT Technique - Reconstruction as Vector Quantity -" The Transactions of the Institute of Electronics, Information and Communication Engineers. J72-D-II. 1839-1847 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Hideo Saito et. al.: "Reconstruction of Magnetic Flux Density as Vector Quantity by CT Technique" IEEE Trans Instrum. Meas.38. 415-420 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Hideo Saito et. al.: "High Speed Data Collection System for Magnetic Field Imaging by CT Technique" IEEE Trans Instrum. Meas.39. 739-744 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Hideo Saito et. al.: "Magnetic Field Imaging by CT Technique - Projection Data Collecting Method by Rotational Scanning -" The Transactions of the Institute of Electronics, Information and Communication Engineers. J74-D-II. 282-284 (1991)