• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1991 Fiscal Year Final Research Report Summary

Development of artificial muscle having characteristics of human skeletal muscle

Research Project

Project/Area Number 01870001
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field General anatomy (including Histology/Embryology)
Research InstitutionTohoku University

Principal Investigator

HANDA Yasunobu  Tohoku Univ. School of Med., Professor, 医学部, 教授 (00111790)

Co-Investigator(Kenkyū-buntansha) IGUCHI Yasutaka  Tohoku Univ. Faculty of Eng., Professor, 工学部, 教授 (90005413)
MURAKMI Hajime  Tohoku Univ. Faculty of Eng., Instructor, 工学部, 助手 (80219899)
HOSHIMIYA Nozomu  Tohoku Univ. Faculty of Eng., Professor, 工学部, 教授 (50005394)
TAKAHASHI Hirotatu  Tohoku Univ. School of Med., Instructor, 医学部, 助手 (50221362)
HANDA Tutomu  Tohoku Univ. School of Med., Instructor, 医学部, 助手 (30208699)
Project Period (FY) 1989 – 1992
KeywordsArtificial Muscle / Dynamic Hand Model / Functional electrical Stimulation / Shape Memory Alloy / 肘関節 / 筋電図 / 機能的電気刺激
Research Abstract

We have developed artificial muscles made of helically colled shape memory alloy (SMA) wires. this SMA was made by diffusion method in order to reduce metal fatigue and to increase force of during transition. The transition temperature of this SMA for the artificial muscle was 75゚C
(Af point). As feasible study of control of the SMA muscle, we made a dynamic model of the artificial hand where sophisticated duplicated skeleton system of the forarm and hand was used. Universal joints for robotics were used as joints for connecting each bone. A stainless steel rope was used as an artificial tendon and attached to the prescribed point of the bone where the tendon of each muscle is originally inserted in human. For applying current to each SMA muscle, a multichannel functional electrical stimulation (FES) system which we developed was used. Patterns of current application to SMA muscles were created from EMG data during hand motion recorded from normal volunteers. By using this system, hand motions such as cylindrical grasp and key grip were achieved in the artificial dynamic hand model.
Then we have developed a muscle unit by a hellically colled SMA wire. Diameter of this wire was 0.1mm and D/d=5. Number of coiling was 100. Force of transition (contractile force) of this muscle unit was 6 kg/cm2 at 63゚C. This value was almost the same as that of human skeletal muscle during maximum contraction. An agonistantagonist system acting to the rabbit elbow joint with the above mentioned FES system was made by connecting the muscle units. It was found that flextion and extension of the elbow was basically controlled by this system.

  • Research Products

    (12 results)

All Other

All Publications (12 results)

  • [Publications] Y.Handa: "A portable multi-channel FES system for restoration of motor function of the paralyzed extremities" Automedica. 11. 221-231 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] N.Hoshimiya: "A master-slave type multi-channel functional electrical stimulation (FES)system for the control of the paralyzed upper extremities" Automedica. 11. 209-220 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 半田 康延: "解剖にいのちを" 東北医誌. 第102巻. 189-192 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 半田 勉: "形状記憶合金をアクチュエ-タとし手の動的モデルの試作" 第10回バイオメカニズム学術講演会誌. 75-78 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 半田 勉: "形状記憶合金製人工筋肉を用いたヒトの動的モデル(第1報)" 解剖学雑誌. 第64巻. 376 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 内藤 輝: "上肢FESのための神経・筋刺激デ-タの作成" 医用電子と生体工学. 第28巻. 50-55 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T. ODA, H. ISHIBE, Y. HANDA, N. HOSHIMIYA: "Restoration of motor function by artificial muscles made of newly developed shape memory alloy" Jap. Soc ME & BE. 26. 278 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T. HANDA, Y. HANDA et al: "Studies on a dyamic hand model actuated by shape memory alloy" Jap. Soc. ME & BE. 27. 185 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Y. HANDA, K. OHKUBO, N. HOSHIMIYA: "A portable multi-channel FES system for restoration of motor function of the paralyzed extremities" Automedica. 11. 221-231 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] N. HOSHIMIYA, Y. HANDA: "A master-slave type multi-channel functional electrical stimulation (FES) system for the control of the paralyzed upper extremities" Automedica. 11. 209-220 (1989)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T. HANDA, Y. HANDA et al: "Control of an FES system controlled by EMG signals" Proc. IEEE/11th Ann. Conf. EMBS. 1-4 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] A. NAITO, Y. SHIMIZU Y. HANDA: "Functional anatomical studies of the elbow movments. I. Elctromyographic (EMG) analysis" Okajima's Folia Anat. Jpn.68. 283-288 (1991)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1993-03-16  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi