2001 Fiscal Year Final Research Report Summary

Effects of scattered X-rays on diagnostic X-ray images

Research Project

Project/Area Number 12650058
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Applied physics, general
Research InstitutionHiroshima Prefectural College of Health Sciences

Principal Investigator

TAKIGAWA Atsushi  Hiroshima Prefectural College of Health Sciences, Faculty of Health Sciences, Professor, 保健福祉学部, 教授 (80197227)

Co-Investigator(Kenkyū-buntansha) NISHIHARA Sadamitsu  Hiroshima Prefectural College of Health Sciences, Faculty of Health Sciences, Research Associate, 保健福祉学部, 助手 (40290548)
Project Period (FY) 2000 – 2001
Keywordsscattered X-rays / image sharpness / anti-scatter grid / air-gap method / patient dose
Research Abstract

We studied three subjects. Firstly, we evaluated the effect of scattered X-rays on the sharpness of X-ray image. Secondly, we compared the elimination efficiency of scattered X-rays for air-gap method and anti-scatter grid method. Thirdly, we evaluated the performance of dosimeter for measuring patient dose.
1. It has been said that the response function of scattered X-rays agree with the primary fraction, when scattered X-rays incident in wide area of the image receptor. However, no report which confirmed the fact has been published as long as we know. We conducted the experiment using square wave chart. As a result, we confirmed the fact.
2. Air-gap method and anti-grid method are often used to eliminate scattered X-rays. However, it is nots clear that which method should be used in radiography. We measured scatter fraction, radiographic contrast and surface dose, changing the thickness of the object, field area, distance of air-gap and anti-scatter grid. As a result, it is clarified that air-gap method is useful when the field area is small enough, nevertheless we must consider how wide the field area is required for diagnosis.
3. Patient dose due to X-ray fluorography has been increased according to the rise in the number of patients who are treated with interventional radiology. For measuring patient surface dose including scattered X-rays in fluorography, some dosimeters have been developed. Skin dose monitor is one of them. We evaluated the performance of the skin dose monitor. It underestimates surface dose when short period fluorography is repeated comparing to one continuous exposure, even total exposure time is the same. We cannot measure surface dose correctly, when X-rays get in the detector in large angle. However, skin dose monitor is very useful to measure surface dose in real time, we hope it will be improved in the near future.

  • Research Products

    (10 results)

All Other

All Publications (10 results)

  • [Publications] 菊地理沙: "スキンドーズモニタを用いた被曝線量の測定"日本放射線技術学会中国・四国部会会誌. 11号. 90 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 山口博嗣: "散乱線分布を考慮したX線撮影時の術者・介助者の位置"日本放射線技術学会中国・四国部会会誌. 11号. 91 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 岡崎憲光: "エアギャップ法とグリッド法の散乱線除去効果の比較"日本放射線技術学会中国・四国部会会誌. 11号. 93 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Yoshiyuki Asai: "Reduction of patient dose on medical radiographs using scattered X-rays"Proceedings of SPIE. 4549. 86-91 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 瀧川 厚: "散乱X線のMTF"医用画像情報学会雑誌. 19. 86-90 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Risa KIKUCHI: "Measurement of patient dose using a skin dose monitor"Journal of Chugoku-Shikoku Branch of Japanese Society of Radiological Technology. No.11. 90 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Hiroshi YAMAGUCHI: "Position of operators and helpers in radiography considering scattered X-ray distribution"Journal of Chugoku-Shikoku Branch of Japanese Society of Radiological Technology. No.11. 91 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Norimitsu OKAZAKI: "Comparison between air-gap method and grid method in the elimination efficiency of scattered X-rays"Journal of Chugoku-Shikoku Branch of Japanese Society of Radiological Technology. No.11. 93 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Yoshiyuki ASAI: "Reduction of patient dose on medical radiographs using scattered X-rays"SPIE. 4549. 86-91 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Atsushi TAKIGAWA: "Effects of scattered X-rays on the sharpness of diagnostic X-ray images"Medical Imaging and Information Sciences. 19(2). 86-90 (2002)

    • Description
      「研究成果報告書概要(欧文)」より