2004 Fiscal Year Final Research Report Summary
Development of Real-Time MR Image guided Surgery
Project/Area Number |
14370352
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
General surgery
|
Research Institution | Shiga University of Medical Science |
Principal Investigator |
KURUMI Yoshimasa Shiga University of Medical Science, Assistant Professor, 医学部, 講師 (70205219)
|
Co-Investigator(Kenkyū-buntansha) |
TANI Tohru Shiga University of Medical Science, Professor, 医学部, 教授 (20179823)
MORIKAWA Shigehiro MR Medical Research Center, Associate Professor, MRI医学総合研究センター, 助教授 (60220042)
ENDO Yoshihiro Shiga University of Medical Science, Instructor, 医学部, 助手 (40263040)
NAKA Shigeyuki Shiga University of Medical Science, Instructor, 医学部, 助手 (10359771)
HANASAWA Kazuyoshi Shiga University of Medical Science, Associate Professor, 医学部, 助教授 (80146406)
|
Project Period (FY) |
2002 – 2004
|
Keywords | Navigation Surgery / Real Time MR Image / Microwave Coagulation Therapy / Open MR / Microwave Surgery / MR Thermal Image / Vertical Open MR / 4 Dimensional Image |
Research Abstract |
Results outline of the research : We have developed Real-time MR image guided surgery system and clarified a new effect of microwave. 1.Real-time MR image guided surgery : Real-time MR image guided surgery is carried out on a 0.5T vertically oriented open MR scanner (SIGNA SP/i). We also developed the original MRI navigation system which consists of a personal computer and integrated into the open MR scanner. The virtual organ image is reconstructed from a previously acquired MR or CT image. The composite image which contains the virtual slice image, real time MR image, temperature monitoring image, virtual 3D image and endoscopic image is shown on the LCD monitor in the bore of open MR scanner. 2.Real-time MR Temperature Monitoring : This technique is useful for the evaluation of microwave electrodes and for the optimization of output power and duration in microwave ablation. Real-time MR temperature images are calculated by the proton resonance frequency method and utilized in MRI navigation system. 3.New Effect of Microwave : Microwave fixation can be considered a type of coagulative necrosis without enzyme digestion. Disruption of erythrocytes on HE staining is an interesting and important diagnostic clue in distinguishing non-viable fixed tissues from viable tissues following microwave coagulation therapy.
|
Research Products
(38 results)
-
-
-
-
-
[Journal Article] Robotic surgery in cancer2005
Author(s)
Yoshimasa KURUMI, Shigehiro MORIKAWA, Shigeyuki NAKA, Hisanori SHIOMI, Hisakazu HOSHI, Tohru TANI
-
Journal Title
New Perspective in Cancer Research and Therapy (In press)
Description
「研究成果報告書概要(欧文)」より
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[Journal Article] New assistive devices for MR-guided microwave thermocoagulation of liver tumors2003
Author(s)
Shigehiro MORIKWAWA, Toshiro INUBUSHI, Yoshimasa KURUMI, Shigeyuki NAKA, Koichiro SATO, Tohru TANI, Hasnine A Haque, Junichi TOKUDA, Nobuhiko HATA, Tani T, Haque HA, Tokuda J, Hata N.
-
Journal Title
Academic Radiology 10
Pages: 180-188
Description
「研究成果報告書概要(欧文)」より
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[Journal Article] Enzyme Histochemistry is Useful to Assess Viability of Tumor Tissue after Microwave Coagulation Therapy2002
Author(s)
Ken-ichi MUKAISHO, Yoshimasa KURUMI, Hiroyuki SUGIHARA, Shigeyuki.NAKA, Yasuhiro TSUBOSA, Suzuko MORITANI, Yoshihiro ENDO, Kazuyoshi HANASAWA, Shigehiro MORIKAWA, Toshiro INUBUSHI, Takanori HATTORI, Tohru TANI
-
Journal Title
Digestive Diseases and Science 47(11)
Pages: 2441-2445
Description