• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2017 Fiscal Year Final Research Report

Fundamental Study to Realize Performance-Based Design of Braced Shear Wall for Any Sized Wooden Frame

Research Project

  • PDF
Project/Area Number 15K06287
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Building structures/Materials
Research InstitutionYokohama National University

Principal Investigator

NAKAO Masato  横浜国立大学, 大学院都市イノベーション研究院, 特別研究教員 (60323937)

Project Period (FY) 2015-04-01 – 2018-03-31
Keywords在来軸組構法 / 木造住宅 / 筋かい耐力壁 / 筋かい金物
Outline of Final Research Achievements

This research was conducted focusing on a braced shear wall installed in wooden houses build by the Post-and-beam construction system. Firstly, static shear loading tests on braced shear walls with three types of brace fastener and three wall length, namely 910 mm, 1365 mm and 1820mm were performed to understand the failure modes and the shear force-story displacement relationships. After that, static incremental analysis of the braced shear walls was conducted, and it was found that the incremental analysis model is adequate for estimating the shear force-story displacement relationships. It was also confirmed that the analysis model is valid for estimating the shear force-story displacement of a knee braced shear wall and a K-shaped brace shear wall. Additionally, trial experiment to examine the design method for the connection between the end of the brace and the frame was conducted to have useful knowledge.

Free Research Field

建築木質構造

URL: 

Published: 2019-03-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI