• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2005 Fiscal Year Final Research Report Summary

Development of vibration sensor with high spatial resolution and visualization of vibration distribution

Research Project

Project/Area Number 16560369
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Measurement engineering
Research InstitutionTakushoku University

Principal Investigator

HASEGAWA Jun  Takushoku Univ., Dept.of Electronics and Computer Systems, Associate Professor, 工学部, 助教授 (30228449)

Project Period (FY) 2004 – 2005
Keywordsvibration distribution / optical sensor / displacement sensor / optical fiber / calibration / visualization
Research Abstract

A multi-channel optical sensor system was developed to measure vibrations simultaneously with high spatial resolution. As sensor elements, non-contact type optical displacement sensor units were developed not to disturb the natural vibration. Each sensor unit consists of optical fiber bundle and focusing lens, and its maximum diameter is 2.5 mm. The optical fiber bundle is used for both light emission and reception, and the displacement of the object can be detected as the variation of the received light power at the photo-detector. The sensor unit has the displacement resolution of 10 nanometer, the dynamic range of more than 90 dB, the frequency band width of up to 80 kHz and the spatial resolution of 4 mm under the simultaneous measurement (focused spot diameter itself was 0.5〜1mm). Up to 64 sensor units can be arrayed as one sensor head, which realizes the simultaneous measurement of vibration distribution with the high spatial resolution of 4mm.Calibrating function was developed for the accurate vibration measurement which did not depend on the reflection characteristics of the vibrating object's surface. Under calibration mode, the sensor array head is moved by a linear actuator, while the vibration of the object is stopped. Thus the calibrated data of each sensor unit can be measured for the displacement magnitude. Measured vibration distributions can be monitored as the 3-dimensional animations. By using this feature, several actuators for vibratory micro-injection were measured, and the system could reveal their detailed vibration distributions and could detect the existence of failure portion of some actuator.

  • Research Products

    (7 results)

All 2006 2005 2004

All Journal Article (7 results)

  • [Journal Article] 光学式振動分布測定システムの開発2006

    • Author(s)
      一本木司, 長谷川淳, 小林健二
    • Journal Title

      電子情報通信学会技術報告 EA2005-105

      Pages: 5-10

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Development and application of Optical vibration distribution measurement system. (In Japanese)2006

    • Author(s)
      Ippongi Tsukasa, Jun Hasegawa, Kenji Kobayashi
    • Journal Title

      The Technical Report of The IEICE EA2005-105

      Pages: 5-10

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] 振動分布計測システムによる人工弁クリック発生要因の検討2005

    • Author(s)
      長谷川 淳, 小林 健二
    • Journal Title

      医用電子と生体工学 43巻特別号

      Pages: 513

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Mechanizm of audible closing click generation of mechanical heart valves. -Application of high spatial resolution vibration measurement system. (In Japanese)2005

    • Author(s)
      Jun Hasegawa, Kenji Kobayashi
    • Journal Title

      Japan Soc.ME & BE (Suppl.)

      Pages: 513

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Development and application of Optical vibration distribution measurement system. (In Japanese)2005

    • Author(s)
      Ippongi Tsukasa, Jun Hasegawa, Kenji Kobayashi
    • Journal Title

      Acoustical Soc.of Japan (Suppl.)

      Pages: 549-550

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] 機械人工弁における可聴領域クリック発生要因の検討 -高空間分解能振動分布計測システムの開発と応用-2004

    • Author(s)
      長谷川 淳, 小林 健二
    • Journal Title

      医用電子と生体工学 42巻特別号

      Pages: 413

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Mechanizm of audible closing click generation of mechanical heart valves. -Application of high spatial resolution vibration measurement system. (In Japanese)2004

    • Author(s)
      Jun Hasegawa, Kenji Kobayashi
    • Journal Title

      Japan Soc.ME & BE (Suppl.)

      Pages: 413

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2007-12-13  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi