2010 Fiscal Year Final Research Report
Evaluation of angular dependence of radiation dose from seeds source for radio-pharmacy by using absolute measurement technique
Project/Area Number |
20560051
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Applied physics, general
|
Research Institution | National Institute of Advanced Industrial Science and Technology |
Principal Investigator |
YUNOKI Akira National Institute of Advanced Industrial Science and Technology, 計測標準研究部門, 室長 (10415763)
|
Research Collaborator |
UNNO Yasuhiro 独立行政法人産業技術総合研究所, 計測標準研究部門, 研究員 (90462837)
|
Project Period (FY) |
2008 – 2010
|
Keywords | 前立腺がん / 放射線治療 / 密封小線源 / ヨウ素125 / 角度依存性 / 大容量自由空気電離箱 / 軟X線検出器 |
Research Abstract |
I-125 brachytherapy sources are widely used for treatment of prostate cancer. It is necessary to investigate the dose angular dependence of the source for purpose of quality control. We assembled a large volume free air chamber and conducted angular distributions of the source with unique jig which enabled us to rotate the source in 3-dimension. We evaluated correction factor and measurement uncertainty. It shows that we measured accurate distributions.
|