Functional MRI microscopy in ultra-low field

Research Project

  • PDF
Project/Area Number 25420406
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Measurement engineering
Research InstitutionKinki University (2014-2015)
Toyohashi University of Technology (2013)

Principal Investigator

HATSUKADE Yoshimi  近畿大学, 工学部, 准教授 (90339713)

Co-Investigator(Renkei-kenkyūsha) TANAKA Saburo  豊橋技術科学大学, 工学(系)研究科(研究院), 教授 (10271602)
YOSHIDA Sachiko  豊橋技術科学大学, 工学(系)研究科(研究院), 講師 (40222393)
Project Period (FY) 2013-04-01 – 2016-03-31
Keywords超低磁場 / NMR / MRI / SQUID / 磁場耐性 / ノイズ除去
Outline of Final Research Achievements

We aimed to develop an ultra-low-field (ULF) NMR/MRI system, which will be basis of functional MRI microscopy in the future. In this study, an ultra-sensitive SQUID magnetic sensor, which has extremely high sensitivity in low frequency range, which correspond to Larmor frequency in ULF, was used in the ULF NMR/MRI system. Using the system, we showed that the signal amplitude and line width of NMR signal in ULF increased and decreased with the static field intensity, respectively. Achievement of MRI in ULF was also demonstrated. We also studied possibility of realization of ULF NMR/MRI in normal environment, by combining robust SQUID and noise cancelling techniques.