We proposed a method to enhance spin-torque diode (STD) sensitivity by using an antiphase dynamic coupling (ADC) of the free and reference layers. The ADC was found in STD measurements of MgO-based magnetic tunnel junctions and also in micromagnetic simulations. In order to investigate the optimal conditions for the ADC, we developed an analytical expression for the STD effect caused by the magnetization dynamics in the reference layers. From the analytical expressions, we found that inducing interaction between the reference and magnetic-pinned layers through the spin torque is more advantageous to the ADC than inducing interaction between the reference and free layers. The analytical expression also made it possible to evaluate quantitatively the spin-torque interactions working on the reference layer.