1986 Fiscal Year Final Research Report Summary

Development and evaluation of motor-driven, pusher-plate-type artificial heart system

Research Project

Project/Area Number 59870046
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field Thoracic surgery
Research InstitutionNational Cardiovascular Center

Principal Investigator

HAYASHI Kozaburo  National Cardiovascular Center, Department Director, その他, 研究員 (90026196)

Co-Investigator(Kenkyū-buntansha) NAKAMURA Takao  National Cardiovascular Center, Research Associate, 研究所生体工学部, 室員 (00142654)
SEKI Junji  National Cardiovascular Center, Research Associate, 研究所生体工学部, 室員 (20163082)
UMEZU Mitsuo  National Cardiovascular Center, Laboratory Head, 研究所人工臓器部, 室長 (90132927)
TAKANO Hisateru  National Cardiovascular Center, Department Director, 研究所人工臓器部, 部長 (60028595)
AKUTSU Tetsuzo  National Cardiovascular Center, Vice Director of Research Institute, 研究所, 副所長 (40150221)
Project Period (FY) 1984 – 1986
KeywordsCardiac assist device / Artificial Heart / Motor / Pusher-plate / Pulse width modulation (PWM) / Microprocessor / ソフトウェア
Research Abstract

A pulse width modulation (PWM) algorithm with fixed duty ratio and variable voltage has been developed to drive and control the implantable electro-mechanical actuator for blood pumps. The actuator incorporated with a dc brushless motor was attached to a pusher-plate-type blood pump. Rotation of the motor is converted into a linear motion by a ball screw. The position of the pusher-pate was monitored with a Hall-effect sensor mounted on the back plate and a magnet attached to the plate. Any other monitors are not necessary for the open-loop operation of the pump. The size of the actuator is 50 mm OD and 30 mm length, and the weight is 480 g. Eight-bit and sixteen-bit microprocessor-based systems were used to drive the motor and to control the whole system, respectively.
The torque performance of the motor assembled in the actuator was studied in detail for the development of the software which controls the speed and the input voltage of the motor without any feed back informations. The results indicated that the pump fulfills the specified performance.
Software was developed based on the results obtained from the torque test. The sixteen-bit microprocessor controls the operation of the pump, monitoring the position of the pusher-plate in the systolic phase and using a timer in the diastole. The eight-bit microprocessor controls the phase of rotating magnetic field and input voltage of the motor according to the data table derived from the torque test.
The system performance studied with a mock circulator satisfied the design specifications. The pump outflow of 6 1/min was obtained at the rate of around 100 bpm against the afterload of 100 mmHg. The temperature rise and the pump efficiency were around 6 % and 18 C, respectively.

  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 中村孝夫 他: 人工臓器. 15. 669-672 (1986)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 中村孝夫 他: 人工臓器. 16. (1987)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 林紘三郎 他,T.Akutsu ed: "Artificial Heart 1" Springer-Verlag, 192 (1986)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Takao NAKAMURA, Kozaburo HAYASHI, and Junji SEKI: "Microprocessor-controlled motor driven implantable cardiac assist device. -Design of driving and control algorithm-" Japanese Journal of Artificial Organs. 15. 669-672 (1986)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Takao NAKAMURA, Kozaburo HAYASHI, and Junji SEKI: "Motor-driven implantable cardiac assist device. -Software development for drive and control-" Japanese Journal of Artificial Organs. 16. (1987)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Kozaburo HAYASHI, Junji SEKI, Takao NAKAMURA, and Hiroyuki FUKUMASU: Springer-Verlag (Artificial Heart 1, ed. by T.AKUTSU). Portable drive unit for artificial heart: Toward the totally implantable system (pp 95-101), 192 (1986)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1988-11-09  