1986 Fiscal Year Final Research Report Summary
Circulatory Management of Venous Return Mechanism during Anesthesia
Project/Area Number |
60480352
|
Research Category |
Grant-in-Aid for General Scientific Research (B)
|
Allocation Type | Single-year Grants |
Research Field |
麻酔学
|
Research Institution | Kurume University |
Principal Investigator |
MUTEKI Takesuke Kurume University School of Medicine, 医学部, 教授 (60080917)
|
Co-Investigator(Kenkyū-buntansha) |
TAKAGI Toshiaki University of Occupational and Environmental Health, School of Medicine, 講師 (90098864)
TSUDA Hideaki Kurume University School of Medicine, 医学部, 助教授 (10080920)
|
Project Period (FY) |
1985 – 1986
|
Keywords | mean systemic pressure / CVP waveform / electromechanical analysis / right atrial function venous return mechanism / 静脈還流抵抗 / 肺血管抵抗 / preload / 循環平均圧 |
Research Abstract |
In order to extend clinical significance of monitoring central venous pressure(CVP),elecrromechanical analysis of CVP waveform has been attempted on surgical patients under anesthesia CVP waveform and other hemo-dynamic parameters were measured and recorded by our fiberoptic pressure monitoring system with Millar's micromanometry. This system was specially designed to achieve not only electric safety but also high fidelity and noise performance and the pressure amplifier was also specially designed with stabilizing circuit to depress base line awaring in order to obtain accurately enlarged CVP waveforms even under surgery with electrocautery. Electromechanical indicies of the a, c and v waves of CVP were obtained for assessment of RV function with a special reference of venous return mechanism.With an identification of Y wave from the CVP wave forms, dynamic mean systemic pressure (d.Pms) has been clinically measured by graphic analysis on the theoretical basis (Hori,M., 1969) by our technique of Valsalva's maneuver during surgery in a state where the heart is functioning. The d.Pms , which was obtained under Halothane anesthesia with 108.5 <+!-> 5.97 mmHg in systolic blood pressure was 7.00 <+!-> 0.65(mean <+!-> SE, n=11),and the resistance of VR(GVR) was calculated by the equation of d.Pms-CVP (y)/VR and 250.8 <+!-> 20.9 dyne sec <cm^(-5)> was obtained. GVR was usually well maintained under a stable condition of circulatory equilibrium (Guyton) under anesthesia. With these experimental results, a new concept for CVP measurement and physiological significance of the resistance of VR was recognized.
|
Research Products
(13 results)
-
-
-
-
-
-
-
-
[Publications] Muteki, T., Aragaki, T., Gotoh, S., Shimizu, D., Sueyoshi, F., Kohno, I., Tokutomi, Y., and Takagi, T.: "Maiatenance of Preload Reserve of Right Sided Cardiac Function by Administration of TNG during Rapid Administration of Plasma Expander (Haemaccel ) under Halothane Anesthesia" The Japanese Journal of Anesthesiology. 6. 945-952 (1985)
Description
「研究成果報告書概要(欧文)」より
-
-
[Publications] Yurino, M., Ohishi, K., Matsuoka, H., Tokutomi, Y., Watanabe, S., Tayama, F. and Muteki, T.: "Non-invasive Investigation of Hemodynamic Effect of Electrical Acupuncture on the Peripheral Vein in the Awake Human" The Journal of Japan Society for Clinical Anesthesia. 6. 381-390 (1986)
Description
「研究成果報告書概要(欧文)」より
-
[Publications] Watanabe, S., Iwakuma, I., Ohishi, K., Gotoh, S., Tsuda, H. and Muteki, T.: "Electrocardiographic and Hemodynamic Changes in Coronary Angiospasm" The Journal of Japan Society for Clinical Anesthesia. 6. 486-492 (1986)
Description
「研究成果報告書概要(欧文)」より
-
[Publications] Ohishi, K., Muteki, T., Shinozaki, M., Aragaki, T., Tagami, M., Shimizu, D. and Takagi, T.: "Clinical Significance of Mean Circulatory of Mean Circulatory Filling Pressure and Cardiac Preload under Anesthesia" J. Anesth.1. 35-43 (1987)
Description
「研究成果報告書概要(欧文)」より
-