• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of Micro analysis of NO and its application

Research Project

Project/Area Number 10672029
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Physical pharmacy
Research InstitutionHoshi University

Principal Investigator

YOSHIMURA Yoshihiro  Hoshi University, Faculty of Pharmacy, Associate Professor, 薬学部, 講師 (00147894)

Co-Investigator(Kenkyū-buntansha) WATANABE Takaho  Hoshi University, Faculty of Pharmacy, Research assistant, 薬学部, 助手 (80210912)
NAKAZAWA Hiroyuki  Hoshi University, Faculty of Pharmacy, Professor, 薬学部, 教授 (50150173)
Project Period (FY) 1998 – 2000
Project Status Completed (Fiscal Year 2000)
Budget Amount *help
¥3,000,000 (Direct Cost: ¥3,000,000)
Fiscal Year 2000: ¥900,000 (Direct Cost: ¥900,000)
Fiscal Year 1999: ¥800,000 (Direct Cost: ¥800,000)
Fiscal Year 1998: ¥1,300,000 (Direct Cost: ¥1,300,000)
KeywordsNitric Oxide / Separation analysis / Electron chemical detection / Spin tapping / Electron spin resonance / ECD / フリーラジカル / 生体試料
Research Abstract

Electron spin resonance (ESR) method was examined for determination of nitric oxide (NO) using Carboxy-PTIO.the Proposed method was 100 nM as detection limit (S/N=3) of NO, and more high sensitivety and saecificitv than these of Grease method and fluorescence method. We developed the HPLC/ECD/ESR system, which be able to separate for the many free radicals, determining each radical within 10 min by using the reverse-phase HPLC.Scince Carboxy-PTIO is easy to oxidize by reductants such as ascorbic acid, tocopherol and uric acid in the organism, good determination for NO could not obtained. Therefore, Liposome- PTIO which was prepared bv using the lecithin, examined stability for determination of NO in the biological systems. It is elucidate that Liposome-PTIO could be protected from many reductants by barrier of lipid bilayer. The good linearity is obtained between 10μM to 100μM, and detection limit (S/N=3) is 5 μM by the ECD detector and 50 nM by ESR.We applied proposed method to determination of NO of lacrimal fluid in rat suffered from conjunctivitis. As the results, generation of 0.4 μM for NO was recognized in the lacrimal fluid of rat. Formation of NO was confirmed in the aorta thoracica of the rat which caused the blood vessel relaxation.