DEVELOPMENT OF A DEVICE FOR NITRIC OXIDE PRODUCTION USING PULSED DISCHARGES

Research Project

Project/Area Number 12557132
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Anesthesiology/Resuscitation studies
Research InstitutionSHINSHU UNIVERSITY (2001-2002)
Kumamoto University (2000)

Principal Investigator

OKAMOTO Kazufumi  SHINSHU UNIV., SCHOOL OF MEDICINE, PROFESSOR, 医学部, 教授 (60093994)

Co-Investigator(Kenkyū-buntansha) HONDA Takayuki  SHINSHU UNIV., SCHOOL OF MEDICINE, ASSO. PROFESSOR, 医学部, 助教授 (80238815)
OKUDERA Hiroshi  SHINSHU UNIV., SCHOOL OF MEDICINE, ASSO. PROFESSOR, 医学部, 助教授 (50252101)
AKIYAMA Hidenori  KUMAMOTO UNIV., TECHNICAL DEPT, PROFESSOR, 工学部, 教授 (50126827)
SHINOHARA Kennji  SHINSHU UNIV., SCHOOL OF MEDICINE, ASSISTANT, 医学部附属病院, 助手 (80293504)
久木田 一朗  熊本大学, 医学部・附属病院, 講師 (60253746)
猪山 賢一  熊本大学, 医学部・附属病院, 助教授 (10040536)
Project Period (FY) 2000 – 2002
Project Status Completed (Fiscal Year 2002)
Budget Amount *help
¥4,700,000 (Direct Cost: ¥4,700,000)
Fiscal Year 2002: ¥2,600,000 (Direct Cost: ¥2,600,000)
Fiscal Year 2001: ¥2,100,000 (Direct Cost: ¥2,100,000)
KeywordsINHALED NITRIC OXIDE / PULSED POWER / ACUTE RESPIRATORY FAILURE / RESPIRATORY DISTRESS SYNDROME OF THE NEONATE / VENTILATOR / 呼吸不全 / 人工呼吸 / 二酸化窒素 / 一酸化窒素 / 肺高血圧
Research Abstract

THE GOAL OF THE PRESENT STUDY WAS TO DEVELOPE A NOVEL DEVICE OF NITRIC OXIDE PRODUCTION USING PULSED DISCHARGES FOR INHALED NITRIC OXIDE THERAPY. A BRASS ELECTRODE WAS USED FOR DISCHARGE. ABOUT 400-500 PPM OF NITRIC OXIDE WAS PRODUCED. THE CONCENTRATION OF NITROGEN DIOXIDE WAS REDUCED USING MOLYBDENUM. BY USING CHARCOAL, THE CONCENTRATION OF NITROGEN DIOXIDE WAS MAINTAINED AT 0 PPM. SMALL AMOUNT OF NITROUS OXIDE WAS ALSO DETECTED. THE DEVICE LASTED 3 MONTHS WITHOUT ANY TROUBLE ALTHOUGH THE ABRASION OF THE ELECTRODE ffAS DETECTED. AN ELECTROMAGNETIC WAVE AND NOISE WERE WITHIN A PERMISSIBLE RANGE. FOR CLINICAL USE, WE HAVE TO CHECK MOREOVER IN DETAIL WHETHER ANYOTHER ABNORMAL GASES ARE NOT PRODUCED BY THE ELECTRICAL DISCHRGES. THE DEVICE CAN BE MINIATURIZED TO LOAD ON A VENTILATOR. INHALED NITRIC OXIDE THERAPY IS OFTEN USED FOR A NEONATE WITH HYPOXEMIC RESPIRATORY FAILURE. THE ANIMAL EXPERIMENT IS REQUIRED TO DETERMINE WHETHER INHALED NITRIC OXIDE THERAPY BY THE DEVICE DO NOT PRODUCE THE PATHOL OGICAL CHANGES OF THE LUNGS IN NEONATE ANIMALS.

Report

(4 results)
  • 2002 Annual Research Report   Final Research Report Summary
  • 2001 Annual Research Report
  • 2000 Annual Research Report
  • Research Products

    (11 results)

All Other

All Publications (11 results)

  • [Publications] Namihira T, Katsuki S, Hackam R, Akiyama H, Okamoto K: "Production of nitric oxide using a pulsed arc discharge"IEEE Transactions on Plasma Science. (In print).

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] 浪平隆男, 勝木淳, 秋山秀典, 岡元和文: "パルスアーク放電プラズマによるNO生成と医療への応用"プラズマ・核融合学会誌. 79. 35-38 (2003)

    • Description
      「研究成果報告書概要(和文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] Namihira T., Katsuki S., Hackam R., Akiyama H., Okamoto K.: IEEE Transactions on Plasma Science. In print

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] Namihira T., Katsuki S., Akiyama H., Okamoto K.: J Plasma Fusion Res. 79(1). 35-38 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
    • Related Report
      2002 Final Research Report Summary
  • [Publications] Namihira T, Katsuki S, Hackam R, Akiyama H, Okamoto K: "Production of nitric oxide using a pulsed are discharge"IEEE Transactions on Plasma Science. (In print).

    • Related Report
      2002 Annual Research Report
  • [Publications] 浪平隆男, 勝木淳, 秋山秀典, 岡元和文: "パルスアーク放電プラズマによるNO生成と医療への応用"プラズマ・核融合学会誌. 79. 35-38 (2003)

    • Related Report
      2002 Annual Research Report
  • [Publications] 岡元和文, 他: "NO吸入療法"日本臨床. 59・6. 1126-1131 (2001)

    • Related Report
      2001 Annual Research Report
  • [Publications] 岡元和文: "NO吸入による肺高血圧治療"外科治療. 82・6. 1157-1158 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Okamoto K, et al: "Combined effects of inhaled nitric oxide and positive end-expiratory pressure during CMD in ARDS."Artif Organs. 24・5. 390-395 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Okamoto K, et al: "Combination of inhaled nitric oxide therapy and IRV in patients with sepsis-associated ARDS."Artif Organs. 24・11. 902-908 (2000)

    • Related Report
      2000 Annual Research Report
  • [Publications] Namohira T, et al: "Production of nitric monoxide using pulsed discharges for a medical application"IEEE Transactions on Plasma Science. 28・1. 109-114 (2000)

    • Related Report
      2000 Annual Research Report

URL: 

Published: 2001-04-01   Modified: 2016-04-21  