• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

A Study on the Thermal / Air Environment in the Industrial Laundry

Research Project

Project/Area Number 15K06335
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Architectural environment/Equipment
Research InstitutionMeisei University

Principal Investigator

OGASARAWA Takeshi  明星大学, 理工学部, 准教授 (30516232)

Project Period (FY) 2015-04-01 – 2018-03-31
Project Status Completed (Fiscal Year 2017)
Budget Amount *help
¥3,120,000 (Direct Cost: ¥2,400,000、Indirect Cost: ¥720,000)
Fiscal Year 2017: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2016: ¥1,560,000 (Direct Cost: ¥1,200,000、Indirect Cost: ¥360,000)
Fiscal Year 2015: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Keywords工場建築 / 温熱環境 / 空気質 / クリーニング工場 / 暑熱環境 / 実測 / アンケート / 快適性 / 労働環境 / 工場
Outline of Final Research Achievements

In this research, an indoor environmental survey was conducted at a commercial cleaning factory. In the survey at factories with different facilities, both factories confirmed that the air temperature inside the factory was 3 ° C higher than the outside air temperature. Even at factories introducing spot air conditioning, it was found that the comfort of the factory is low.
In the comparative survey before and after the roof renovation, it was confirmed that the indoor side roof surface temperature was lowered by about 4 ° C. by the heat insulating refurbishment. According to the questionnaire survey, in response to overall thermal feeling question, the unpleasant reply was 57% before the renovation, but it was 20% after the renovation.

Report

(4 results)
  • 2017 Annual Research Report   Final Research Report ( PDF )
  • 2016 Research-status Report
  • 2015 Research-status Report
  • Research Products

    (3 results)

All 2017

All Presentation (3 results) (of which Invited: 1 results)

  • [Presentation] (1)クリーニング工場内の温熱・空気環境に関する研究 (第1報)異なる工場を対象とした夏期アンケート調査2017

    • Author(s)
      小笠原 岳
    • Organizer
      空気調和・衛生工学会
    • Related Report
      2017 Annual Research Report
  • [Presentation] (2)クリーニング工場内の温熱環境に関する研究 (その3)空調・換気設備の異なる工場内の夏期環境比較2017

    • Author(s)
      小笠原 岳
    • Organizer
      日本建築学会
    • Related Report
      2017 Annual Research Report
  • [Presentation] クリーニング工場における温熱・空気環境に関する基礎的研究2017

    • Author(s)
      小笠原 岳
    • Organizer
      テクノトランスファーかわさき2017
    • Related Report
      2017 Annual Research Report
    • Invited

URL: 

Published: 2015-04-16   Modified: 2019-03-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI