Budget Amount *help |
¥4,550,000 (Direct Cost: ¥3,500,000、Indirect Cost: ¥1,050,000)
Fiscal Year 2011: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2010: ¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Fiscal Year 2009: ¥2,210,000 (Direct Cost: ¥1,700,000、Indirect Cost: ¥510,000)
|
Research Abstract |
This study is examined for four problems to do the most suitable design of a direct water supply system. 1) Suggestion of a new second flow quantity calculation method : suggested calculation method considers a household numerical change of late years, the spread of a saving water appliance. 2) Evaluation of energy for direct water supply system : energy evaluation is done for a direct connection increase pressure water supply system, in addition, a flow quantity estimate of an increase pressure pump is done. 3) Elucidation of dissatisfaction flow quantity : flow quantity to be dissatisfied for water use act is decided. 4) Solution of demand performance for booster direct water supply system : demand performance for a system is elucidated.
|