Study of High Speed and High Precision Performance for Measurement of Distal shape and Position in Dose Distribution in Proton Beam Therapy

Research Project

Project/Area Number 21591606
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionUniversity of Tsukuba

Principal Investigator

YASUOKA Kiyoshi  筑波大学, 医学医療系, 講師 (50200499)

Project Period (FY) 2009 – 2011
Project Status Completed (Fiscal Year 2011)
Budget Amount *help
¥2,860,000 (Direct Cost: ¥2,200,000、Indirect Cost: ¥660,000)
Fiscal Year 2011: ¥910,000 (Direct Cost: ¥700,000、Indirect Cost: ¥210,000)
Fiscal Year 2010: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2009: ¥1,300,000 (Direct Cost: ¥1,000,000、Indirect Cost: ¥300,000)
Keywords粒子線 / 線量分布 / シンチレータ / CCDカメラ / 陽子線 / 検出器 / クエンチング / 線量校正
Research Abstract

The system of scintillating plate with a wedge-type range shifter has been confirmed practically useful for a supporting system in appropriate determination of calibration constants in reasonable consuming time of 3 minutes and adequate precision.

Report

(4 results)
  • 2011 Annual Research Report   Final Research Report ( PDF )
  • 2010 Annual Research Report
  • 2009 Annual Research Report
  • Research Products

    (6 results)

All 2011 2010

All Journal Article (2 results) Presentation (4 results)

  • [Journal Article]2010

    • Author(s)
      柳田広務, 安岡聖, 照沼利之, 熊田博明, 井汲晋, 榮武二
    • Journal Title

      Japanese Journal ofMedical Physics

      Volume: 30巻 Pages: 207-208

    • Related Report
      2011 Final Research Report
  • [Journal Article] Verification of practically usable system in measurement of dose distribution and proper decision for calibration constants used in proton therapy at PMRC.2010

    • Author(s)
      Hiromu Yanagida
    • Journal Title

      Japanese Journal of Medical Physics

      Volume: 30 Pages: 207-208

    • Related Report
      2010 Annual Research Report
  • [Presentation] A Supporting SystemApplied to Precisely Determining Calibration Constants for each Patientat PMRC in Proton Beam Therapy2011

    • Author(s)
      Kiyoshi Yasuoka, Hiromu Yanagida, Toshiyuki Terunuma, Hiroaki Kumada, Takeji Sakae
    • Organizer
      The 50^<th> Particle Therapy C0-Operative Group Conference (PTCOG50)
    • Place of Presentation
      Philadelphia, USA
    • Related Report
      2011 Final Research Report
  • [Presentation] A Supporting System Applied to Precisely Determining Calibration Constants for each Patient at PMRC in Proton Beam Therapy2011

    • Author(s)
      Kiyoshi Yasuoka
    • Organizer
      Particle Therapy CO-Operative Group (PTCOG)
    • Place of Presentation
      米国フィラデルフィア
    • Related Report
      2011 Annual Research Report
  • [Presentation] PMRCにおける複雑な部位形状に対する適性判断のためのシンチレータ板型線量分布確認システムの実用化についての検証2010

    • Author(s)
      柳田広務, 安岡聖, 照沼利之, 熊田博明, 井汲晋, 榮武二
    • Organizer
      第100回日本医学物理学会学術大会
    • Place of Presentation
      学術総合センター、東京都千代田区、日本
    • Related Report
      2011 Final Research Report
  • [Presentation] PMRCにおける複雑な部位形状に対する適性判断のためのシンチレータ板型線量分布確認システムの実用化についての検証2010

    • Author(s)
      安岡聖
    • Organizer
      日本医学物理学会
    • Place of Presentation
      学術総合センター(東京都)
    • Related Report
      2010 Annual Research Report

URL: 

Published: 2009-04-01   Modified: 2016-04-21  