Outline of Final Research Achievements |
A lot of seismic damages of hanging type mechanical structure in industrial facilities were occurred in Great East Japan Earthquake, and the industrial functions stopped at many facilities. This study has been carried out to upgrade the seismic safety improvement of hanging type mechanical structure in several industrial and plant facilities from analytical and experimental approaches. As the results, it was confirmed that the conservation of function and seismic safety of hanging type mechanical structure are obtained by following conditions including countermeasure for afterquake. One is that the frequency ratio between main structure and hanging type mechanical structure should be over 1.1 or under 0.9, and the other is that the damping ratio in the vibration system of hanging type mechanical structure should be over 20%.
|