• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of dose verification program using plastic scintilation detector

Research Project

Project/Area Number 24791300
Research Category

Grant-in-Aid for Young Scientists (B)

Allocation TypeMulti-year Fund
Research Field Radiation science
Research InstitutionOsaka University

Principal Investigator

SUMIDA Iori  大阪大学, 医学(系)研究科(研究院), 助教 (10425431)

Project Period (FY) 2012-04-01 – 2014-03-31
Project Status Completed (Fiscal Year 2013)
Budget Amount *help
¥1,430,000 (Direct Cost: ¥1,100,000、Indirect Cost: ¥330,000)
Fiscal Year 2013: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2012: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Keywords放射線治療物理学 / シンチレータ / CCDカメラ / 線量分布 / QA/QC / 強度変調放射線治療 / リアルタイム / シンチレーション光 / 線量検証 / QA / プラスティックシンチレータ
Research Abstract

In general radiographic film or radiochromic film are used to verify the dose idstribution. Although the characteristic of the film is superior for the spatial resolution, the handling of film is complecated and there is uncertainty for the convert between density and absorbed dose. In this study the new radiation detector using scintilation light named plastic scintilator was chosen to verify the dose distribution. The CCD camera was used to detect the scintilation light. With respect to the beam output, the linearity and reproducibility were evaluated with plastic scintilation detector and compared with the ionization chamber as a reference. It was found that the good agreement between two detectors except very low monitor unit which was not usually used in general radiation treatment. Finally the dose vefirication for intensity modulated radiation therapy was performed using plastic scintilation detector. There were also good agreement between measurements and calculations.

Report

(3 results)
  • 2013 Annual Research Report   Final Research Report ( PDF )
  • 2012 Research-status Report
  • Research Products

    (4 results)

All 2014 2012

All Journal Article (2 results) (of which Peer Reviewed: 1 results) Presentation (2 results)

  • [Journal Article] Evaluation of imaging performance for megavoltage cone-beam CT over an extended period2014

    • Author(s)
      Sumida I, Yamaguchi H, Kizaki H, Yamada Y, Koizumi M, Yoshioka Y, Ogawa K, Kakimoto N, Murakami S, Furukawa S
    • Journal Title

      J Radiat Res

      Volume: 55 Pages: 191-199

    • Related Report
      2013 Final Research Report
  • [Journal Article] Evaluation of imaging performance of megavoltage cone-beam CT over an extended period2014

    • Author(s)
      Sumida I, Yamaguchi H, Kizaki H, Yamada Y, Koizumi M, Yoshioka Y, Ogawa K, Kakimoto N, Murakami S, Furukawa S.
    • Journal Title

      J Radiat Res.

      Volume: 55 Issue: 1 Pages: 191-9

    • DOI

      10.1093/jrr/rrt100

    • Related Report
      2013 Annual Research Report
    • Peer Reviewed
  • [Presentation] プラスティックシンチレーション検出器を用いた線量検証システム構築の基礎的検討2012

    • Author(s)
      隅田伊織, 他
    • Organizer
      第25回日本放射線腫瘍学会
    • Place of Presentation
      東京
    • Related Report
      2013 Final Research Report
  • [Presentation] プラスティックシンチレーション検出器を用いた線量検証システム構築の基礎的検討2012

    • Author(s)
      隅田伊織
    • Organizer
      第25回日本放射線腫瘍学会
    • Place of Presentation
      東京国際フォーラム
    • Related Report
      2012 Research-status Report

URL: 

Published: 2013-05-31   Modified: 2019-07-29  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi