• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

A study on accurately and rapidly estimate exposure dose in X-ray CT

Research Project

Project/Area Number 26460727
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Medical Physics and Radiological Technology
Research InstitutionNagoya University

Principal Investigator

Koyama Shuji  名古屋大学, 脳とこころの研究センター, 准教授 (20242878)

Research Collaborator HABA Tomonobu  
INOUE Masaki  
SHIBAHARA Tomoki  
KAKUTA Naoya  
TSUTSUMI Yoshinori  
KAMEYAMA Hiroshi  
TODA Naohiro  
Project Period (FY) 2014-04-01 – 2017-03-31
Project Status Completed (Fiscal Year 2016)
Budget Amount *help
¥5,070,000 (Direct Cost: ¥3,900,000、Indirect Cost: ¥1,170,000)
Fiscal Year 2016: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2015: ¥1,560,000 (Direct Cost: ¥1,200,000、Indirect Cost: ¥360,000)
Fiscal Year 2014: ¥2,860,000 (Direct Cost: ¥2,200,000、Indirect Cost: ¥660,000)
Keywords放射線技術学 / 医療被ばく / 放射線計測 / X線CT / モンテカルロシミュレーション / X線CT
Outline of Final Research Achievements

In order to perform accurate Monte Carlo simulation of X-ray CT, we developed an 8-channel X-ray energy analyzer and a single-channel spherical semiconductor dosimeter. The former is for measuring the X-ray energy and dose intensity for each fan angle of X-ray fan beams which are different for each model and scan condition of X-ray CT, and the latter is for accurately measuring the state of the X-ray tube current modulation during the CT scan. The basic data of various CT units obtained using these instruments were incorporated into the simulation code, and it was confirmed that the actual measurement and the calculation by the anthropomorphic phantom are consistent. Finally, Monte Carlo simulation by parallel calculation based on actual subject data was performed to estimate the organ dose.

Report

(4 results)
  • 2016 Annual Research Report   Final Research Report ( PDF )
  • 2015 Research-status Report
  • 2014 Research-status Report
  • Research Products

    (22 results)

All 2016 2015 2014

All Journal Article (10 results) (of which Open Access: 5 results,  Peer Reviewed: 4 results,  Acknowledgement Compliant: 3 results) Presentation (12 results) (of which Invited: 2 results)

  • [Journal Article] CTにおける医療被曝の指標2016

    • Author(s)
      小山修司
    • Journal Title

      日獨医報

      Volume: 61(1) Pages: 13-25

    • Related Report
      2016 Annual Research Report
    • Open Access
  • [Journal Article] Influence of 320-detector-row volume scanning and AAPM report 111 CT dosimetry metrics on size-specific dose estimate: a Monte Carlo study2016

    • Author(s)
      HABA Tomonobu, KOYAMA Shuji, KINOMURA Yutaka, IDA Yoshihiro, KOBAYASHI Masanao
    • Journal Title

      Australasian Physical & Engineering Sciences in Medicine

      Volume: 39(3) Issue: 3 Pages: 697-703

    • DOI

      10.1007/s13246-016-0465-7

    • Related Report
      2016 Annual Research Report
    • Peer Reviewed
  • [Journal Article] Pin-photodiode array for the measurement of fan-beam energy and air kerma distributions of X-ray CT scanners2016

    • Author(s)
      HABA Tomonobu, KOYAMA Shuji, AOYAMA Takahiko, KINOMURA Yutaka, IDA Yoshihiro, KOBAYASHI Masanao, KAMEYAMA Hiroshi, TSUTSUMI Yoshinori
    • Journal Title

      Physica Medica

      Volume: 32 Issue: 7 Pages: 905-913

    • DOI

      10.1016/j.ejmp.2016.06.010

    • Related Report
      2016 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] A Monte Carlo Simulation based on Measured Tube Current Modulation Data in X-Ray Computed Tomography2015

    • Author(s)
      INOUE Masaki, KOYAMA Shuji, HABA Tomonobu, SHIBAHARA Tomoki
    • Journal Title

      Proceedings of the Twenty-Second EGS Users' Meeting in Japan

      Volume: 2015(6) Pages: 17-24

    • Related Report
      2015 Research-status Report
    • Open Access / Acknowledgement Compliant
  • [Journal Article] Relationship between the Tube Voltage Dependence of Cross-sectional Ab- sorbed Profile and Exposed Dose of Superficial Radiosensitive Organs2015

    • Author(s)
      SHIBAHARA Tomoki, KOYAMA Shuji, INOUE Masaki, HABA Tomonobu
    • Journal Title

      Proceedings of the Twenty-Second EGS Users' Meeting in Japan

      Volume: 2015(6) Pages: 25-32

    • Related Report
      2015 Research-status Report
    • Open Access / Acknowledgement Compliant
  • [Journal Article] 8. Application of the Monte Carlo Simulation 5: X-ray CT2015

    • Author(s)
      小山修司
    • Journal Title

      Japanese Journal of Radiological Technology

      Volume: 71 Issue: 4 Pages: 371-379

    • DOI

      10.6009/jjrt.2015_JSRT_71.4.371

    • NAID

      130005064926

    • ISSN
      0369-4305, 1881-4883
    • Related Report
      2015 Research-status Report
  • [Journal Article] フラットパネルディテクタによる3Dローテーションアンギオグラフィ,コーンビームCTの被ばく線量評価2014

    • Author(s)
      瀬口繁信,西條貴哉,石川芳信,小山修司
    • Journal Title

      日本放射線技術学会雑誌

      Volume: 70(7) Pages: 646-652

    • NAID

      130004776291

    • Related Report
      2014 Research-status Report
    • Peer Reviewed / Open Access
  • [Journal Article] An examination of difference in absorbed dose profile between measurement and calculation in X-ray computed tomography2014

    • Author(s)
      Masaki Inoue, Shuji Koyama, Naoya Kakuta, Tomonobu Haba
    • Journal Title

      Proceedings of the Twenty-First EGS User's Meeting in Japan

      Volume: 2014(6) Pages: 13-17

    • Related Report
      2014 Research-status Report
    • Open Access
  • [Journal Article] 物理評価の進歩:Dual Energy における測定法2014

    • Author(s)
      小山修司
    • Journal Title

      インナービジョン

      Volume: 29(10) Pages: 27-31

    • Related Report
      2014 Research-status Report
  • [Journal Article] X 線 CT における深部線量分布の実測とモンテカルロシミュレーション2014

    • Author(s)
      井上政輝,小山修司,角田尚矢,堤 貴紀,遠藤真紀
    • Journal Title

      Proceedings of the JSCT

      Volume: 2 Pages: 48-50

    • Related Report
      2014 Research-status Report
    • Peer Reviewed
  • [Presentation] X線CTにおける円柱状水ファントム内部の実効エネルギーの解析2016

    • Author(s)
      羽場友信,小山修司,小林正尚,井田義宏,木野村豊
    • Organizer
      第 9 回中部放射線医療技術学術大会
    • Place of Presentation
      鈴鹿
    • Year and Date
      2016-11-06
    • Related Report
      2016 Annual Research Report
  • [Presentation] Weighted CTDIにおける最適な荷重係数の検討2016

    • Author(s)
      羽場友信,小山修司,小林正尚,木野村豊
    • Organizer
      第44回日本放射線技術学会秋期学術大会
    • Place of Presentation
      大宮
    • Year and Date
      2016-10-14
    • Related Report
      2016 Annual Research Report
  • [Presentation] 汎用コードEGS5とX線CTでの応用2015

    • Author(s)
      小山修司
    • Organizer
      第43回日本放射線技術学会秋季学術大会
    • Place of Presentation
      金沢市
    • Year and Date
      2015-10-08
    • Related Report
      2015 Research-status Report
    • Invited
  • [Presentation] X線CT装置での実測管電流変調データに基づくモンテカルロシミュレーション2015

    • Author(s)
      井上政輝,小山修司,羽場友信,芝原与喜
    • Organizer
      第22回EGS研究会
    • Place of Presentation
      つくば市
    • Year and Date
      2015-08-02
    • Related Report
      2015 Research-status Report
  • [Presentation] X線CTにおけるファントム内線量分布の管電圧依存性と体表部臓器被ばくの関係2015

    • Author(s)
      芝原与喜,小山修司,井上政輝,羽場友信
    • Organizer
      第22回EGS研究会
    • Place of Presentation
      つくば市
    • Year and Date
      2015-08-02
    • Related Report
      2015 Research-status Report
  • [Presentation] 最新のX線CT線量測定の動向2015

    • Author(s)
      小山修司
    • Organizer
      第46回岐阜県診療放射線技師会X線CT研究会
    • Place of Presentation
      三重県養老郡
    • Year and Date
      2015-05-16
    • Related Report
      2015 Research-status Report
    • Invited
  • [Presentation] X線CTで実測によって得られた管電流変調データを用いた人体ファントムの表面線量の評価2015

    • Author(s)
      井上政輝,小山修司,芝原与喜,堤 貴紀,古川悌史
    • Organizer
      第71回日本放射線技術学会総会学術大会
    • Place of Presentation
      パシフィコ横浜(横浜市)
    • Year and Date
      2015-04-16 – 2015-04-19
    • Related Report
      2014 Research-status Report
  • [Presentation] Development of multichannel semiconductor sensors to measure effective energies with a rotating exposure mode in X-ray CT2015

    • Author(s)
      Tomonobu HABA, Shuji KOYAMA, Hiroshi KAMEYAMA, Masanao KOBAYASHI, Yoshihiro IDA, Yutaka KINOMURA, Takahiko AOYAMA
    • Organizer
      第71回日本放射線技術学会総会学術大会
    • Place of Presentation
      パシフィコ横浜(横浜市)
    • Year and Date
      2015-04-16 – 2015-04-19
    • Related Report
      2014 Research-status Report
  • [Presentation] X線CTにおける回転照射下での実行エネルギー測定を可能とする多チャンネル半導体検出器の開発2015

    • Author(s)
      羽場友信,小山修司,角田尚矢,小林正尚,井田義宏,木野村豊
    • Organizer
      第71回日本放射線技術学会学術大会
    • Place of Presentation
      横浜市
    • Year and Date
      2015-04-16
    • Related Report
      2015 Research-status Report
  • [Presentation] 胸部CTにおける Dose Modulation 機構を用いた 乳腺被ばく線量低減法の検討2015

    • Author(s)
      馬渕龍,大野和子,小山修司,小泉幸司
    • Organizer
      第71回日本放射線技術学会学術大会
    • Place of Presentation
      横浜市
    • Year and Date
      2015-04-16
    • Related Report
      2015 Research-status Report
  • [Presentation] X線CTで実測によって得られた 管電流変調データを用いた 人体ファントムの表面線量の評価2015

    • Author(s)
      井上政輝,小山修司,芝原与喜,堤貴紀,古川悌史
    • Organizer
      第71回日本放射線技術学会学術大会
    • Place of Presentation
      横浜市
    • Year and Date
      2015-04-16
    • Related Report
      2015 Research-status Report
  • [Presentation] X線CT装置における半導体線量計を用いた管電流変調データの取得2014

    • Author(s)
      井上政輝,小山修司,角田尚矢,堤 貴紀,古川悌史
    • Organizer
      第42回日本放射線技術学会秋季学術大会
    • Place of Presentation
      札幌コンベンションセンター(札幌市)
    • Year and Date
      2014-10-09 – 2014-10-11
    • Related Report
      2014 Research-status Report

URL: 

Published: 2014-04-04   Modified: 2018-03-22  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI