• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1992 Fiscal Year Final Research Report Summary

Development of Integrated Electrostatic Linear Actuator as Biomimicking Skeletal Muscle.

Research Project

Project/Area Number 02452133
Research Category

Grant-in-Aid for General Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field 機械力学・制御工学
Research InstitutionTokyo Women's Medical College

Principal Investigator

KABEI Nobuyuki  Tokyo Women's Medical College Assistant Professor, 医学部, 講師 (50096583)

Co-Investigator(Kenkyū-buntansha) TSUCHIYA Kiichi  Waseda University. Professor : OF POSITION, 理工学部, 教授 (70063469)
Project Period (FY) 1990 – 1992
KeywordsElectrostatic Motor / Artificial Muscle / Micro-electromechanical-system / Electrostatics Actuator / Linear Motor / Micro Manufacturing / マイクロマシン / 微細加工
Research Abstract

We applied the technology of biomimicry to the development of an artificial muscle using a new theory of muscle contraction, termed the electrostatic linear motor model which proposed by Dr. Yano.
The fundamental actuator consists of a parallel plate capacitor and a slider made of dielectric material. When the capacitor is charged or discharged at the appropriate intervals, an electric potential energy is converted into mechanical energy for pulling the slider into the space of the charged capacitor.
The following were revealed through the analysis and experiments using fundamental units and the integrated actuator.
1) There are no differences among many patterns of layout of electrodes which are placed on the both sides of a stator.
2) The optimal aspect ratio (length of electrode / distance between two electrodes) of one pair of electrodes is 0.8.
3) The optimal driving frequency range for botaining high force was from 5 to 10 kHZ.
4) The output force increased in proportion to the second power of applied voltage. The force of 10 mN was obtained at 250 V.
5) One hundred of unit actuators were three dimensionally integrated (width 44 x length 44 x thickness 8.82 mm). Its total output force was 32 mN which was generated under the driving voltage of 100 V. Thus,the force density of 1.87 kN/m^3 was obtained.
6) Continuous driving of the integrated linear actuator was achieved. The actuator moved continuously and smoothly for long distance.
Since the three dimensionally integrated actuator can be manufactured using state-of-the-art techniques, it has potential practical use.

  • Research Products

    (3 results)

All Other

All Publications (3 results)

  • [Publications] Kabei et al: "Theoretical analysis of an electrostatic linear actuator developed as a biomimiking skeletal muscle." JSME International Journal Series3. Vol.35. 400-405 (1992)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 壁井 信之他,阿岸 鉄三編: "人工臓器'92.第4章第1節新しいタイプの人工臓器." 中山書店, 317 (1992)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 壁井 信之,マイクロマシン技術による製品小型化・知能化事典編集委員会編: "マイクロマシン技術による製品小型化・知能化事典第3編第4章第8節液電中で動く静電アクチュエータ." (株)産業調査会・事典出版センター, 916 (1992)

    • Description
      「研究成果報告書概要(和文)」より

URL: 

Published: 1994-03-24  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI