Clinical Application of High Strength poly (L-Lactide) with Osteoductivity

Research Project

Project/Area Number 05671214
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field Orthopaedic surgery
Research InstitutionKYOTO UNIVERSITY

Principal Investigator

KITSUGI Toshiaki  Kyoto University Faculty of Medicine Instructor, 医学部, 助手 (10240821)

Co-Investigator(Kenkyū-buntansha) IKADA Yoshito  Kyoto University Res.Cent.for Biomed.Eng.Professor, 生体医療工学研究センター, 教授 (00025909)
MATSUSUE Yoshitaka  Kyoto University Faculty of Medicine Lecturer, 医学部, 講師 (30209548)
Project Period (FY) 1993 – 1994
KeywordsBioactive / Biodegradable / poly (L-lactide) / Osteoconduction / Composite / Aw-glass ceramic
Research Abstract

Ultra high strength poly (L-lactide) osteosynthetic implants (rods and screws) which we have developed in recent years was confirmed to be safety and its long-term histological tissue reaction has also been clarified. A new bioactive composite made of poly (L-lactide) with AW-glass ceramic coated on its surface was studied in vivo. After implantation into the rabbit tibiae, animals were sacrificed with time and a detaching test was performed. The values of detaching tests was very low, ranging from zero to 300 grams, and separation occurred in the interface (coating layr) between poly (L-lactide) and AW-glass ceramic. The degradation of poly (L-lactide) delayd at 18 and 24 months after implantation. From this study, it has been demonstrated that the coating layr was the most critical week point on the new bioactive composite made of poly (L-lactide) with AW-glass ceramic. It is considered that this noble material cannot be used clinically unless both materials are re-manufactured into a stable structure with some different methods.
We also performed another experiments using drawn poly (L-lactide) films with piezo-electricity in a rabbit bone defect model. Drawn poly (L-lactide) films by 4 : 1 showed a significantly better osteoconductivity that that of undrawn ones. Drawn poly (L-lactide) films by 4 : 1 and polyethylene films as a control were compared, and the former had a much bone volume. In the future, drawn poly (L-lactide) films can be used as a model for repair of bone defect in combination with osteoinductive factors such as BMP.

  • Research Products

    (12 results)

All Other

All Publications (12 results)

  • [Publications] 松末,吉隆: "Biodegadable Screw Fixation of Rabbit Tibia Proxiual Osteomies" Journal Applied Biomaterials. 2(1). 1-12 (1991)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 松末,吉隆: "Invitro and Invivo Studies on Bioaksorbable Ultra-High-Strengtn Poly(1-Lactide)Rods" J.Biomed.Mater.Res.26. 1553-1567 (1992)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 山室隆夫: "Aclinical Study on Bioabsorbable Osteosynthetic Implants Made of Ultra-High-Strength Poly-L-Lactide" Int.Orthop(SICOT). 18. 332-340 (1994)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 松末吉隆: "生体内吸収性骨接合材" 整形外科. 46. 269-276 (1995)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 松末吉隆: "Tissue Reaction of Bioabsorbable Ultra High Strength Pcly (L-Lactide)Red:A Long Term Study in Rabbits" Clin.Orthop.(印刷中). (1995)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 花房信哉: "A Comparative Stydy using Dual Energy X-ray Absorptimetry" Clin.Orthop.313(印刷中). (1995)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Yoshitaka Matsusue: "Biodegradable Screw Fixation of Rabbit Tibia Proximal Osteotomies" J.Applied.Biomat. 2 (1). 1-12 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Yoshitka Matsuse: "In vitro and In vivo Studies on Bioabsorbable Ultra-High-Strength Poly (I-Lactide) Rods" J.Biomed.Mater.Res. 26. 1553-1567 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Takao Yamamuro: "A clinical Study on Bioabsorbable Osteosynthetic Implants Made of Ultra-High-Strength Poly-L-Lactide" Int.Orthop. (SICOT). 18. 332-340

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Yoshitaka Matsusue: "Tissue Reaction of Bioabsorbable Ultra High Strength Poly (L-Lactide) Rod : A Longterm Study in Rabbits" Clin.Crthop.(in press). (1995)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Shinya Hanafusa: "A Comparative Study using Dual Energy X-ray Absorptiometry" Clin Orthop.313 (in press). (1995)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Toshiaki Kitsugi: "Bonding Behavior of A Glass-Ceramic Containing Apatite and Wallastonite in Segmental Replacement of the Rabbit Tibia Load-bearing Conditions" J.Bone Joint Surg. 71-A. 264-272 (1989)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1996-04-15  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi