1997 Fiscal Year Final Research Report Summary

Development of C-mos Real Time Digitral Imaging Device

Research Project

Project/Area Number 07457196
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionUniversity of Tokyo

Principal Investigator

AOKI Yukimasa  University of Tokyo, Radiology, Associate Professor, 医学部・付属病院, 助教授 (40143474)

Co-Investigator(Kenkyū-buntansha) MIZUNO Seiichiro  Hamamatsu Photonics Co., Solid state devision, researcher, 電子管技術部, 専任部員
ONOGI Yuzo  University of Tokyo, Medical Information, Assistant Professor, 医学部・附属病院, 講師 (90233593)
NAKAGAWA Keiichi  University of Tokyo, Radiology, Assistant Professor, 医学部・附属病院, 講師 (80188896)
Project Period (FY) 1995 – 1997
KeywordsFlat-panel detector / C-MOS / real time detector
Research Abstract

Flat-panel, self-scanning, solid-state diagnostic x-ray imaging device using complementary metal-oxide-semiconductor (C-MOS) arrays are under investigation. A unit device with a 5 cm by 5 cm sensor area was developed and tested. The device consists CsI scintillator and C-MOS detector arrays. The detector arrays are composed of a regular arrangement of pixels (256X256), each of which is made of a C-MOS photodiode sensor coupled to a C-MOS FET (field effect transistor. There is a common FET gate line which is connected to all the FET gates along each column. A common date line is connected to all the FET drains of each row. The source contact of each FET is connected to that of its corresponding photodiode. A positive gate pulse applied to a gate turns on all FETs connected to the gate. This causes the image charge to flow to a bank of charge amplifiers connected to the data lines. The readout continues column by column. Correlated double sampling circuits, and offset variance compensation circuit were installed to reduce noise. Sampling speed of 15 frames per second and spatial resolution of 2.5 lines per mm were achieved. Noise level and maximum signal were 1.5 mV rms and 1.8V.Image quality was thought acceptable for clinical use. It is also descussed how to fabricate a large area sensor with the unit device. 10 cm by 10 cm sensor detector was investigated using 4 sets of 5 cm by 5 cm sensors.

  • Research Products

    (12 results)

All Other

All Publications (12 results)

  • [Publications] Aoki Y, et al.: "Clinical evaluation of Gamma knife radiosurgery for intracranial arteriovenoius malformation" Radiation Medicine. 14. 265-268 (1996)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Tago M, Aoki Y, et al.: "Gamma kife radiosurgery for brain stem metastases:Two autopsy cases" Stereotactic Functional Neurosurgery. 66. 225-230 (1997)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Aoki Y, et. al.: "Dose evaluation of patients receiving totalbody irradiation for The pre-treatment of bone marrow:transplantation" Radiation Protection Dosimetry. 71. 61-64 (1997)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Nakagawa K, Aoki Y, et al.: "Argatroban in the treatment of radiation injury of the hand:a case report" Current Therapeutic Research. 58. 323-329 (1997)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Nakagawa K, Aoki Y, et al.: "Improvement of Image Quality In Megavoltage Computed Tomgraphy with Second Generation Scanning Mode" Radiation Oncology Investigation. 5. 257-263 (1997)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Nakagawa K, Aoki Y, et al.: "High dose conformal radiotherapy influenced pattern of failure,but did not improve survival of glioblastoma multiforme" Int J Radiat Oncol Biol Phys. (in print).

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Aoki Y,et al.: "Clinical evaluation of Gamma knife radiosurgery for intracranial arteriovenouius malformation." Radiation Medicine. 14. 265-268 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Tago M,Aoki Y,et al: "Gamma knife radiosurgery for brain stem metastases : Two autopsy cases Stereotactic Functional" Neurosurgery. 66. 225-230 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Aoki Y,et al: "Dose evaluation of patients receiving total-body irradiation for the pre-treatment of bone marrow transplantation." Radiation Protection Dosimetry. 71. 61-64 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Nakagawa K,Aoki Y,et al: "Argatroban in the treatment of radiation injury of the hand : a case report." Current Therapeutic Research. 58. 323-329 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Nakagawa K,Aoki Y,et al: "Improvement Of Image Quality In Megavoltage Computed Tomography With Second Generation Scanning Mode" Radiation Oncology Investigation. 5. 257-263 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Nakagawa K,Aoki Y,et al: "High dose conformal radiotherapy influenced pattern of failure, but did not improve survival of glioblastoma multiforme" Int J Radiat Oncol Biol Phys. (in print).

    • Description
      「研究成果報告書概要(欧文)」より