• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1999 Fiscal Year Final Research Report Summary

A fundamental study for a newly devised DSA system consisted of cooled CCD camera.

Research Project

Project/Area Number 09670914
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionTOHOKU UNIVERSITY

Principal Investigator

ZUGUCHI Masayuki  Tohoku University, Department of Radiological Technology, College of Medical Sciences, Professor., 医療技術短期大学部, 教授 (20172075)

Co-Investigator(Kenkyū-buntansha) SUZUKI Shogo  Tohoku University, Department of Radiological Technology, College of Medical Sciences, Honorary Professor., 医療技術短期大学部, 教授 (00004870)
OOISHI Mikio  Tohoku University, Department of Radiological Technology, College of Medical Sciences, Assistant Professor., 医療技術短期大学部, 助教授 (20004921)
SAITOU Haruo  Tohoku University, Department of Radiological Lecturer., 医学部, 助手 (90170521)
OGURA Takahide  Tohoku University, Department of Radiological Technology, College of Medical Sciences, Assistant., 医療技術短期大学部, 助手 (10312688)
HONMA Noriyasu  Tohoku University, Department of Radiological Technology, College of Medical Sciences, Assistant Professor., 医療技術短期大学部, 助教授 (30282023)
CHIDA Kouichi  Tohoku University, Department of Radiological Technology, College of Medical Sciences, Assistant.
Project Period (FY) 1997 – 1999
KeywordsCooled CCD Camera / IV-DSA / DSA / Angiography
Research Abstract

An investigation of a newly devised DSA system consisted of a cooled CCD camera has been made from 1997 to 2000. Since the cooled CCD camera has markedly high contrast resolution, we have considered that the new system should be competent for IV-DSA. The DSA system had been constructed at first, which consisted of X-ray generator, optical unit and digital processing unit. Then the capability of the system for imaging bad been tested. According to the result of the practice examination using artificial blood vessel, we judged the contrast resolution of the image detected by our new system was better than that by the conventional DSA. Finally an animal experiment had been performed using rabbits, and the branches of the thoracic and abdominal aorta had been demonstrated clearly by the contrast medium administrated from their earlobe vein. Then we considered that this system might be available enough for IV-DSA for human beings.

  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] 洞口正之他: "冷却CCDカメラを用いたIVDSAシステムの基礎的研究"INNERVISION. 14. 52-52 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Masayuki Zuguchi, Haruo Saitou, Mikio Ooishi, Shogo Suzuki, Noriyasu Honnma: "A fundamental study for a newly devised DSA system consisted of cooled CCD camera"INNERVISION. 14-8. 52 (1999)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2001-10-23  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI