• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1998 Fiscal Year Final Research Report Summary

Development of an Apparatus for Flabby Tissue Diagnosis

Research Project

Project/Area Number 09671999
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field 補綴理工系歯学
Research InstitutionKagoshima University

Principal Investigator

HAMANO Tohru  Dental Hospital, Kagoshima University Assistant Professor, 歯学部・附属病院, 講師 (60172988)

Co-Investigator(Kenkyū-buntansha) TSURU Kazunori  Dental Hospital, Kagoshima University Research Associate, 歯学部・附属病院, 助手 (90274844)
KISHITA Chie  Dental School, Kagoshima University Research Associate, 歯学部, 助手 (40264436)
NISHI Yasuhiro  Dental Hospital, Kagoshima University Research Associate, 歯学部・附属病院, 助手 (10189251)
KAWAHATA Naotsugu  Dental School, Kagoshima University Associate Professor, 歯学部, 助教授 (20144511)
NAGAOKA Eiichi  Dental School, Kagoshima University Professor, 歯学部, 教授 (00028812)
Project Period (FY) 1997 – 1998
KeywordsFlabby Tissue / Diagnostic Apparatus / Percussion / Shock Wave
Research Abstract

We investigated the hardening characteristics of impression materials for impression making of flabby tissue and the impression methods of flabby tissue using custom trays. And we applied the results to the patients having the maxillary edentulous ridge with flabby tissue.
And, when only prosthodontic treatment was not enough to recover the oral function of those patients, we applied the method for reconstructing the maxillary edentulous ridges with flabby tissue by application of hydroxyapatite granules (flabby ridge reconstruction method FRR method) to them, and obtained the good courses. However, after applying the FRR method, the flabby tissue had rarely disappeared but almost remained and been removed.
No apparatus was suitable to examine the above-mentioned properties of flabby tissue, and the palpation only was depended. The purpose of this study was to develop an apparatus which evaluate objectively the flabby tissue and evaluate the usefulness.
The trial diagnostic apparatus for flabby tissue was composed of the measuring part with the continuous percussible device and the instrument measuring the displacements and the analyzing part for observing and analyzing waves.
The models with the flabby tissue simulated the different conditions of bone support and real flabby tissue of patients were measured using this apparatus. We evaluated them by the maximum amplitude and decrement time of observed waves.
The trial diagnostic apparatus for flabby tissue could distinguish 27 simulation models and be applied to patients. in the future, we must collect more clinical data with this apparatus and improve the complicated apparatus.

  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] 濱野 徹: "フラビーティッシュ診断装置の開発" 日本補綴歯科学会雑誌. 43(101). (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Tohru Hamano: "Development of an Apparatus for Flabby Tissue Diagnosis" The Journal of the Japan Prosthodontic Society. Vol.43・101st Special Issue. (1999)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1999-12-08  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi