• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1999 Fiscal Year Final Research Report Summary

Developement of miniature TOF/MS for cometary research

Research Project

Project/Area Number 10044085
Research Category

Grant-in-Aid for Scientific Research (B).

Allocation TypeSingle-year Grants
Section一般
Research Field Space and upper atmospheric physics
Research InstitutionOsaka University

Principal Investigator

ISHIHARA Morio  Graduate School of Science, Osaka University, Associate Professor, 大学院・理学研究科, 助教授 (30294151)

Co-Investigator(Kenkyū-buntansha) TOYODA Michisato  Graduate School of Science, Osaka University, Research Assistant, 大学院・理学研究科, 助手 (80283828)
ITO Hiroyuki  Graduate School of Science, Osaka University, Research Assistant, 大学院・理学研究科, 助手 (60223179)
KATAKUSE Itsuo  Graduate School of Science, Osaka University, Professor, 大学院・理学研究科, 教授 (10028235)
Project Period (FY) 1998 – 1999
KeywordsMulti-turn time-of-flight mass spectrometer / Miniature mass spectrometer / planetary and cometary research / lon optics / マルチイオン源 / 小型・軽量
Research Abstract

In space science, mass spectrometry plays a key role in the analysis of material from planetary and cometary surfaces. Mass spectrometry is able to provide information on 1) the isotope ratios of the elements and 2) the possibility of the existence of organic compounds. In the COSAC project of the ROSETTA mission, to be launched in 2003, a mass spectrometer will be loaded on the lander RoLand in order to analyze the material on the surface of comet 46P/Wirtanen.
We have designed and constructed a new type of multi-turn time of flight mass spectrometer as a laboratory model of this COSAC project. The newly constructed miniature TOF/MS comprises of four electric sectors and eight electric quadrupole lenses. Since this instrument employs the multi-turn ion-optical geometry, the flight time is proportional to the number of turns. Therefore, it can be expected that the mass resolution is also proportional to the number of turns. Some test experiments were carried out using air and Xe as test samples. It have been demonstrated by experiment that the mass resolution can increase according to the number of cycles and the ion transmission through the system is more than 90% after one cycle. The mass resolution was 15000 (m/z=28, FWHM) after 100 cycles.

  • Research Products

    (10 results)

All Other

All Publications (10 results)

  • [Publications] Takekiyo Matsuo: "Ion Optics for Multi-tum Time-of-flight Mass Spectrometers with Variable Mass Resolution"Advances in Mass Spectrometry. 14. B04_3510 (1998)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Takekiyo Matsuo: "A Space of Time-of-flight Mass Spectrometer for Exobiologically-Oriented Applications"Advances in Space Research. 23. 341-348 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Michisato Toyoda: "Computer Program "TRIO-DRAW" for Displaying Ion Trajectory and Flight Time"NIM. A427. 375-381 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Morio Ishihara: "Perfect Special and Isochronous Focussing Ion Optics for Multi-tum Time of Flight Mass Spectrometers"Int. J. Mass Spectrom. Ion Processes. 197. 179-189 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Michisato Toyoda: "Construction of a New Multi-tum Time-of-Flight Mass Spectrometer"J. Mass Spectrom.. 35. 163-167 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Matsuo: "Ion Optics for Multi-turn Time of Flight Mass Spectrometers of Eight Figure Geometry"Advances in Mass Spectrometry. 14. B04-3510 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Matsuo: "A Space Time-of-Flight Mass Spectrometer for Exobiologically-Oriented Applications"Nucl. Instrum.Meth.. A427. 375-381 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M.Toyoda: "Computer Program "TRIO-DRAW" for Displaying Ion Trajectory and Flight Time"Advances in Space Research. Vol.23,No.2. 375-381 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M.Ishihara: "Perfect Spacial and Isochronous Focussing Ion Optics for Multi-turn Time of Flight Mass Spectrometer"Int.J.Massspectrom.Ion Processes. 197. 179-189 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M.Toyoda: "Construction of a New Multi turn Time-of-Flight Mass Spectrometer"J.MassSpectrom.. 35. 163-167 (2000)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2001-10-23  