Joint research on a technique of LODERS imaging.

Research Project

Project/Area Number 11694109
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field 分離・精製・検出法
Research InstitutionINSTITUTE FOR LIFE SUPPORT TECHNOLOGY(ILST), YAMAGATA PUBLIC CORPORATION FOR THE DEVELOPMENT OF INDUSTRY

Principal Investigator

OHTA Hiroaki  INSTITUTE FOR LIFE SUPPORT TECHNOLOGY(ILST), DEPUTY DIRECTOR GENERAL, 生物ラジカル研究所, 副所長 (00025389)

Co-Investigator(Kenkyū-buntansha) YOKOYAMA Hidekatsu  INSTITUTE FORLIFE SUPPORT TECHNOLOGY(ILST), SENIOR RESEARCHER, 生物ラジカル研究所, 主幹研究員 (10281619)
SATO Toshiyuki  INSTITUTE FOR LIFE SUPPORT TECHNOLOGY(ILST), CHIEF(YRIT), 生物ラジカル研究所, 開発研究専門員 (80281616)
Project Period (FY) 1999 – 2001
Keywordselectron spin / imaging_ / in vivo / microwave / resonator / longuitudinal relaxation time
Research Abstract

Although imaging by longitudinally detected electron spin resonance (LODESR) method is a developing technique, institutes where the LODESR method has been actively researched are only our institute and University of Aberdeen. In this study, the joint research of the LODESR method was performed by these institutes. The results in our institute are development of, (1) a mutilayered element resonator for highly sensitive detection of LODESR signal, (2) a high-power low-Q RF resonator for pulse techniques, and (3) a LODESR magnetometer for wide range measurements of low fields. On the other hand, in University of Aberdeen, (4) a LODESR analyzing technique as a function of detecting frequency was developed. As a result of the joint research, (5) a pulsed LODESR measuring method at various intervals of π-pulses was developed. This is also a result of an application of (2), and makes it possible to determine longitudinal relaxation times. Measuring relaxation times is a method where the characteristics of LODESR are well utilized.

  • Research Products

    (12 results)

All Other

All Publications (12 results)

  • [Publications] Yokoyama H., Sato T., Fukui K., Ohya-Nishiguchi H., Kamada H.: "High-power low-Q RF ESR resonator for pulse techniques"Chem. Lett.. 919-920 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Sato T., Yokoyama H., Ohya H., Kamada H.: "Measuring method of longitudinally detected ESR signal intensities against resonant frequencies at 250 to 950 MHz in a constant microwave field"Appl. Magn. Reson. 16. 33-43 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Sato T., Yokoyama H., Ohya H., Kamada H.: "A mutilayered element resonator for CW-ESR and longitudinally detected ESR at radio frequency"Appl. Magn. Reson. 17. 119-131 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Yokoyama, H., Sato, T., Ohya, H., Kamada, H.: "Longitudinally Detected ESR Magnetometer for Wide Range Measurements of Low Fields"J. Magn. Reson. 150. 194-197 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Panagiotelis I, Nicholson I, Foster MA, Hutchison JM: "T^*_<1e> and T^*_<2e> maps derived in vivo from the rat using longitudinally detected electron spin resonance phase imaging : application to abdominal oxygen mapping"Magn Reson Med. 46. 1223-1232 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Panagiotelis I, Nicholson I, Hutchison JM: "Electron spin relaxation time measurements using radiofrequency longitudinally detected ESR and application in oximetry"J. Magn. Reson. 149. 74-84 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Yokoyama H., Sato T., Fnkui K., Ohya-Nishiguchi H., Kamada H: "High-power low-Q RF ESR resonator for pulse techniques."Chem. Lett. 919-920 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Sato T., Yokoyama H., Ohya H., Kamada H.: "Measuring method of longitudinally detected ESR signalintensities against resonant frequencies at 250 to 950 MHz in a constant microwave field."Appl. Magn. Reson. 16. 33-43 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Sato T., Yokoyama H., Ohya H., Kamada H.: "Amutilayered element resonator for CW-ESR and longitudinally detected ESR at radio frequency."Appl. Magn. Reson. 17. 119-131 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Yokoyama, H., Sato, T., Ohya, H., Kamada, H.: "Longitudinally Detected ESR Magnetometer for Wide Range Measurements of Low Fields."J. Magn. Reson. 150. 194-197 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Panagiotelis I, Nicholson I, Foster MA, Hutchison JM: "T*_<ic> and T*_<2e> maps derived in vivo from the rat using longitudinally detected electron spin resonance phase imaging : application to abdominal oxygen mapping."Magn Reson Med. 46. 1223-1232 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Panagiotelis I, Nicholson I, Hutchison JM.: "Electron spin relaxation time measurements using radio frequency longitudinally detected ESR and application in oximetry"J. Magn. Reson. 149. 74-84 (2001)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 