Outline of Final Research Achievements |
This study was intended to establish a noninvasive method that assess functional images from PET images acquired with sequential inhalation of 15O-oxygen and 15O-carbondioxide. Arterial input function (AIF) was obtained from PET images, by drawing regions-of-interest (ROI) on the internal carotid artery (ICA) with the recovery and spillover correction from assumed functional values in a referenced tissue area. The functional values were compared with the values from blood sampled method. While the absolute errors in the estimated functional values were mainly dependent on the errors in cerebral blood flow value of the referenced region, the difference in the relative functional values against referenced area were less than 10% in 2SD.
|
Free Research Field |
放射線科学
|