2018 Fiscal Year Final Research Report
Bone strength measurement method by finite element analysis in consideration of qualitative factor of bone collagen
Project/Area Number |
16K10886
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Orthopaedic surgery
|
Research Institution | Chiba University |
Principal Investigator |
|
Co-Investigator(Kenkyū-buntansha) |
鈴木 崇根 千葉大学, 大学院医学研究院, 講師 (30513072)
大鳥 精司 千葉大学, 大学院医学研究院, 教授 (40361430)
國吉 一樹 千葉大学, 大学院医学研究院, 准教授 (40375788)
|
Project Period (FY) |
2016-04-01 – 2019-03-31
|
Keywords | 骨強度 |
Outline of Final Research Achievements |
Bone strength is determined from bone quality and bone mass (bone density). Bone quality includes not only structural elements but also elements of collagen. In recent years, due to technological innovation, bone strength can measured using CT data. However, it did not include all elements of bone quality, and accurate bone strength measurement could not be performed. This study demonstrated that It is possible to measure more accurate by using a simulation method (finite element model). We established a finite element model that incorporates elements of collagen to create a high model
|
Free Research Field |
整形外科
|
Academic Significance and Societal Importance of the Research Achievements |
脆弱性骨折に伴う社会的経済的な損失は計り知れない。現在は骨密度のみの骨粗鬆症診断に依存するため、正確な骨粗鬆症の診断ができず、脆弱性骨折を来す患者があとを絶えない。正確な骨強度を測定することで、骨密度低下を伴わない骨粗鬆症を発見し、脆弱性骨折を予防できる。 また、このモデルを使うことで、手術のシミュレー-ション、術式の決定に貢献でき、テーラーメイドな医療に貢献できる。
|