2021 Fiscal Year Final Research Report
Ultimate Strength and Structural Health Monitoring of Reinforced Concrete Pile Foundation
Project/Area Number |
19K04709
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Review Section |
Basic Section 23010:Building structures and materials-related
|
Research Institution | Chiba University (2021) Toyohashi University of Technology (2019-2020) |
Principal Investigator |
|
Project Period (FY) |
2019-04-01 – 2022-03-31
|
Keywords | 鉄筋コンクリート杭 / 巨大地震 / 損傷 / 耐力評価 / 遠心場実験 / 連成系 / 数値解析 / 地震観測 |
Outline of Final Research Achievements |
This study targets the ultimate state of einforced concrete pile foundation structures. The details are as follows; 1. Centrifugal loading tests of dry sand-RC pile foundation interaction were conducted to clarify the nonlinear behavior of the system and the fracture properties of the RC pile members. 2. A numerical analysis model capable of reproducing the nonlinear behavior of dry sand-RC pile foundation interaction system was proposed and compared with the experimental results. 3. An observation system was constructed and operated to collect earthquake wave data at the real buildings.
|
Free Research Field |
地震工学
|
Academic Significance and Societal Importance of the Research Achievements |
近年の巨大地震では、社会基盤である大型建築物を支える杭部材の損傷が多数みられるようになっており、地震後の事業継続性に大きな影響を及ぼすことが示唆されている。本研究成果は、災害後の事業継続の根幹を支える建物の損傷制御を前提とした設計法構築の基盤となるものである。また、目視確認が難しい地中の構造物である杭部材について、地震時の記録からその損傷を判定する技術の開発をめざし、その端緒となる破壊時応答を記録から同定する方法を提案した。当該成果は、速やかな事業復旧・継続に資するものである。
|