2022 Fiscal Year Final Research Report
Immunity Noise Evaluation and Development of Countermeasure for Resistive Load of Switching Power Supply
Project/Area Number |
20K04431
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Review Section |
Basic Section 21010:Power engineering-related
|
Research Institution | National Institute of Technology, Toyama College |
Principal Investigator |
|
Project Period (FY) |
2020-04-01 – 2023-03-31
|
Keywords | スイッチング電源 / 実負荷 / 電磁両立性 / イミュニティ / バーストノイズ |
Outline of Final Research Achievements |
In this research, as a quantitative index for the immunity performance of a switching power supply unit, we examined the evaluation based on the magnitude of noise transmitted to the load side. As a specific evaluation method, we measured the transmission noise of the burst noise applied voltage that caused the actual load to malfunction using a spectrum analyzer, and verified whether the noise level that causes the actual load to malfunction matches in multiple types of power supplies. If the malfunction level of the actual load can be grasped on the load side of the switching power supply, it will be possible for the power supply manufacturer to develop the power supply considering the effect on the actual load, and it will be possible to aim for smoother immunity countermeasures.
|
Free Research Field |
スイッチング電源,EMCノイズ
|
Academic Significance and Societal Importance of the Research Achievements |
本研究で得られた結果は、1)実負荷が誤動作する負荷側に透過するノイズレベルは周波数依存性を検討する必要があるがおよそ同一であると特定できたこと、2)スイッチング電源単体のイミュニティ評価に加え、負荷側に透過するノイズのレベルを測定することで、実負荷の誤動作を考慮した検討ができることが見いだせたことである。本評価方法を適用し、抵抗負荷で行う電源単体のイミュニティ評価において、透過ノイズが実負荷の誤動作レベル未満を予め確認することで、実負荷側のイミュニティ対策が容易になる。これによって実負荷側のノイズ対策に起因するリメイクに費やす時間・コスト軽減につながることが期待できる。
|