2013 Fiscal Year Final Research Report
Window opening/closing decision algorithms for window advisory monitor
Project/Area Number |
23560703
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Architectural environment/equipment
|
Research Institution | Tokyo University of Science |
Principal Investigator |
NAGAI Tatsuo 東京理科大学, 工学部, 教授 (00316001)
|
Project Period (FY) |
2011 – 2013
|
Keywords | 住宅 / 通風 / 冷房 / エネルギー / 開口部 / 窓 |
Research Abstract |
The research established decision rules implemented in Window advisory monitor, which suggests to occupants in a residential building whether window/door openings should be opened or closed. The purpose of the suggestion is to reduce cooling load due to air-conditioning, and increase amount of time during which windows open. Through use of computer simulation, decision rules have been established. Those rules suggest i) opening windows while air-conditioning is recommended or not, ii) which openings in the building should be opened, iii) windows should be opened or not when occupants leave the house, etc. Computational simulation suggests the energy savings from use of the Window advisory monitor are minor, but the amount of time increases during which windows open, which leads to comfortable indoor environment during summer.
|