2013 Fiscal Year Final Research Report
Development of Measurement Method of Heat Pump Performance for Heating and Cooling by Utilizing Performance Identification Test for Compressor
Project/Area Number |
23686085
|
Research Category |
Grant-in-Aid for Young Scientists (A)
|
Allocation Type | Single-year Grants |
Research Field |
Architectural environment/equipment
|
Research Institution | National Institute for Land and Infrastructure Management |
Principal Investigator |
MIURA Hisashi 国土技術政策総合研究所, 住宅研究部, 主任研究官 (40414966)
|
Project Period (FY) |
2011-04-01 – 2014-03-31
|
Keywords | 建築設備 / フィールド計測 / コンプレッサー / ルームエアコンディショナー |
Research Abstract |
In order to clarify the actual in-situ energy efficiency of room air conditioners, the method to evaluate the heating and cooling capacity by measuring refrigerant based on the refrigerant enthalpy method was considered. The refrigerant flow rate and pressures and so on were measured in artificial climate chambers, and an estimation method for refrigerant flow rate were tested. Heating and cooling load calculated by refrigerant flow was compared with heating and cooling load measured by air enthalpy method in the internal unit.
|
Research Products
(4 results)