Ultra-high b-value diffusion-weighted MRI for the detection of prostate cancer with 3-tesla MRI

Research Project

  • PDF
Project/Area Number 23791427
Research Category

Grant-in-Aid for Young Scientists (B)

Allocation TypeMulti-year Fund
Research Field Radiation science
Research InstitutionKobe University

Principal Investigator

KITAJIMA Kazuhiro  神戸大学, 医学部附属病院, 特命講師 (80448860)

Project Period (FY) 2011 – 2012
Keywords核磁気共鳴画像(MRI)
Research Abstract

We demonstrated that the apparent diffusion coefficient (ADC) obtained using both Ultra-high b value(b = 2,000 s/mm2)and Standard-high b-value(b=1,000 s/mm2)upon 3 Tesla diffusion-weighted MRI is useful for discriminating malignant from normal prostate tissue and predicting the aggressiveness of prostate cancer, using histopathological findings of radical prostatectomy as a reference.

  • Research Products

    (9 results)

All 2012 2011 Other

All Journal Article (2 results) (of which Peer Reviewed: 2 results) Presentation (7 results)

  • [Journal Article] Clinical utility of apparent diffusion coefficient values obtained using high b-value when diagnosing prostate cancer using 3 tesla MRI: comparison between ultra-high b-value (2000 s/mm2) and standard high b-value (1000 s/mm2)2012

    • Author(s)
      Kitajima Kazuhiro, Takahashi Satoru, Ueno Yoshiko, Yoshikawa Takeshi, Ohno Yoshiharu, Obara Makoto, Miyake Hideaki, Fujisawa Makoto, Sugimura Kazuro
    • Journal Title

      J Magn Reson Imaging

      Volume: 36 Pages: 198-205

    • DOI

      DOI:10.1002/jmri.23627.

    • Peer Reviewed
  • [Journal Article] Ultra-high b-value diffusion-weighted MRI for the detection of prostate cancer with 3-T MRI

    • Author(s)
      eno Yoshiko, Kitajima Kazuhiro, Sugimura Kazuro, Kawakami Fumi, Miyake Hideaki, Obara Makoto, Takahashi Satoru
    • Journal Title

      J Magn Reson Imaging

    • DOI

      DOI:10.1002/jmri.23953

    • Peer Reviewed
  • [Presentation] Differentiation of malignant and normal tissues of the prostate by apparent diffusion coefficient values at 3-Tesla MRI: Comparison between ultra-high b-value (2,000 s/mm2) and standard-high b-value (1,000 s/mm2).2012

    • Author(s)
      Kitajima Kazuhiro, Takahashi Satoru, Ueno Yoshiko, Aoyama Nobukazu, Sugimura Kazuro.
    • Organizer
      OCR2012 (The 14th Asian Oceanian Congress of Radiology)
    • Place of Presentation
      Sydney Australia
    • Year and Date
      2012-09-02
  • [Presentation] 3テスラMRI装置での拡散強調画像における、視覚的な前立腺癌検出能に与えるb値の影響2012

    • Author(s)
      上野嘉子、北島一宏、高橋哲、青山信和、吉川武、大野良治、藤井正彦、三宅秀明、川光秀昭、杉村和朗
    • Organizer
      第71回日本医学放射線学会総会
    • Place of Presentation
      横浜
    • Year and Date
      2012-04-15
  • [Presentation] 前立腺癌検出における 3 テスラMRI装置の拡散強調画像の至適high b値の検討2011

    • Author(s)
      上野嘉子、北島一宏、高橋哲、青山信和、大野良治、藤井正彦、三宅秀明、藤澤正人、川光秀昭、杉村和朗。
    • Organizer
      第7回泌尿器腫瘍放射線研究会
    • Place of Presentation
      名古屋
    • Year and Date
      2011-10-29
  • [Presentation] 前立腺癌検出における 3 テスラMRI装置の拡散強調画像の至適high b値の検討。2011

    • Author(s)
      上野嘉子、北島一宏、高橋哲、青山信和、大野良治、藤井正彦、三宅秀明、藤澤正人、川光秀昭、杉村和朗
    • Organizer
      第39回日本磁気共鳴医学会大会
    • Place of Presentation
      小倉
    • Year and Date
      2011-10-01
  • [Presentation] 3T MRI装置でのUltra high b value(b=2000s/mm2)によるADC値を用いた前立腺癌検出能の検討:b=1000との比較。2011

    • Author(s)
      北島一宏、高橋哲、上野嘉子、青山信和、大野良治、藤井正彦、三宅秀明、藤澤沢正人、川光秀昭、杉村和朗
    • Organizer
      第39回日本磁気共鳴医学会大会
    • Place of Presentation
      小倉
    • Year and Date
      2011-10-01
  • [Presentation] Differentiation of prostate malignant and normal peripheral tissues by ADC at 3-T MRI: Comparison between b=2,000 and 1,000 s/mm22011

    • Author(s)
      Kitajima K azuhiro, Takahashi Satoru, Maeda Tetsuo, Ueno Yoshiko, Yoshikawa Takeshi, Fujii Masahiko, Ohno Yoshiharu, Miyake Hideaki, Fujisawa Masato, Sugimura Kazuro.
    • Organizer
      ACAR The 3rdAsian Congress of Abdominal Radiology
    • Place of Presentation
      Beijing China
    • Year and Date
      2011-05-15
  • [Presentation] 3T MRI装置でのUltra high b valueによるADC値を用いた前立腺辺縁域癌の質的診断能の検討2011

    • Author(s)
      北島一宏、高橋哲、前田哲雄、吉川武、青山信和、竹中篤、藤澤正人、大野良治、藤井正彦、杉村和朗
    • Organizer
      第70回日本医学放射線学会総会
    • Place of Presentation
      横浜
    • Year and Date
      2011-04-10

URL: 

Published: 2014-09-25  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI