Research Abstract

Recently great progress has been made in the field of assisted circulation and total artificial heart. The pneumatic driving units available today for the artificial heart are bulky and stationary. In the near future, when an application of an artificial heart to a severe cardiac desease becomes the choice of clinical treatment, a portable driving unit for a blood pump will be required. Therefore, the development of a new system for a portable unit was pursued.
As for a portable energy source of this system, commercially available Ni-Cd battery was used. A scroll compressor was selected as a portable size compressor. To reduce the number of parts to be assembled, a new type of pneumatic system was employed. The system has two compressors. These compressors were arranged in a series. The first stage compressor generates vacuum pressure and right heart driving pressure. The second stage compressor generates left heart driving pressure. Thus left heart driving pressure was generated by multistage compression. all positive pressure levels were controlled by changin the output flow rate of both compressors. Vacuum pressure level was controlled by changing the air volume inside the circuit.
A one chip microcomputer was used for control of these pressure levels. This computer was also applied for the protection against the energy shortage of the battery, pressure sensor break down and computer runaway. A keyboard was used for a man-machine interface. Password was required to operate this system and to change the preset values of the driving conditions for the safety of the patients. Total weight of the unit was about 15 kg. It was confirmed that the unit could drive the blood pump continuously for more 1 hours.

  • Research Products

    (4 results)

All Other

All Publications (4 results)

  • [Publications] 壁井信之、桜井靖久、土屋喜一: 人工臓器. 17(3). 1015-1018 (1988)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 土屋喜一、壁井信之: "人工臓器工学-設計と開発の方法論-" 講談社, 225 (1988)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kabei, N.; Sakurai, Y.; Tsuchiya, K..: "A PORTABLE HEART DRIVER" Jpn. J. Artif. Organs. 17(3). 1015-1018 (1988)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Tsuchita, K.; Kabei, N.; Ed. Atsumi, K.; Fujimasa, I.; Otsubo, O..: ARTIFICIAL ORGANS ENGINEERING. Koudansya, 225 (1988)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1990-12-19  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi