• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1989 Fiscal Year Final Research Report Summary

A Developmental Study of Automatic Canal Filing System

Research Project

Project/Area Number 62870076
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field Conservative dentistry
Research InstitutionNihon University

Principal Investigator

SAITO Tuyoshi  Nihon University, School of Dentistry, Professor, 歯学部, 教授 (60059235)

Co-Investigator(Kenkyū-buntansha) YAMAOKA Masaru  Nihon University, School of Dentistry, Assistant, 歯学部, 助手 (60182408)
TAMURA Kazuya  Nihon University, School of Dentistry, Assistant, 歯学部, 助手 (70197573)
ARIIZUMI Minoru  Nihon University, School of Dentistry, Assistant, 歯学部, 助手 (50159505)
OGISO Bunnai  Nihon University, School of Dentistry, Assistant, 歯学部, 助手 (70147643)
KOMORI Norio  Nihon University, School of Dentistry, Assistant, 歯学部, 助手 (60153681)
Project Period (FY) 1987 – 1989
KeywordsThe measuring of canal length / Electrical measurement of canal length / Canal enlargement / Automatic root canal enlargement / Automatic root canal sharpening / Automatic filing system
Research Abstract

The present study relates generally to dental equipments for treating a root canal and in particular, to a system for detecting the apical portion of a root canal while automatically enlarging the root canal. Such detection has been difficult if the root canal is moisturized with liquid medicines or blood, in conventional electrical equipments.
In accordance with the present study, two input signals having different frequencies are superposed. The difference between impedances corresponding to the two different frequencies at a given position in the root canal where the impedances may hardly vary, is obtained. This value and a clinically determined value are used to detect the apical portion of the root canal.
1. Characteristic features of this new device were as follows: (1)This device is capable of accurately detecting any position in the root canal, even the potion of the apical foramen where impedances may vary widely due to the presence of liquid medicines or blood. The system is, therefore,fully operable under any condition while enlarging the root canal. (2)Diameters of the apical foramen showed little influence on the indicated value. (3)The size of the root canal electrode showed little influence on the indicated value. (4)The concentrations of sodium hypochlorite clinically employed showed little influence on the indicated values.
2. Automatic root canal instrumentation may be carried out by combination of this new device and mechanical equipment, such as electrical engine, ultrasonic and subsonic.

  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 山岡大,山下豊,斎藤毅: "新しい原理による電気的根管長測定器ー湿潤根管で測定できるEMRー" Zoom-Up. 66. 4-9 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 山岡大,山下豊,斎藤毅: "湿潤状態で測定できる電気的根管長測定器APITの臨床" DENTIST. 164. 2-9 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 山下豊: "周波数応答の相対値を応用した根管長測定器の研究とくに根尖孔の径・根管電極の太さ、NaOCl溶液の濃度の影響" 日本歯科保存学会誌. 33. (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Yamaoka et al.: "Electrical Root Canal Measuring Instrument based on New Principle" ZOOM UP, Vol.66, P4-9 (1989).

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Saito et al.: "APIT, EMR, Measurable in Moisturized Condition" DENTIST, Vol.164, P2-9 (1989).

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Y.Yamashita: "A Study of a New Electronic Root Canal Measuring Device Using Relative Values of Frequency Response -Influences of the diameter of Apical Foramen, The Size of Electrode and the Concentration of sodium hypochlorite-" Japan.J.Conserv.Dent., Vol.33, P389-400 (1990).

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1993-03-26  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi