• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1989 Fiscal Year Final Research Report Summary

Development of Mossbauer spectroscopic microanalyzer X-ray analyzer

Research Project

Project/Area Number 63840013
Research Category

Grant-in-Aid for Developmental Scientific Research

Allocation TypeSingle-year Grants
Research Field 物理化学一般
Research InstitutionTokyo Metropolitan University

Principal Investigator

SANO Hirotoshi  Tokyo Metoropolitan Univ. Fac. Of Sci. Professor, 理学部, 教授 (20086995)

Co-Investigator(Kenkyū-buntansha) OOSAWA Takao  Seiko Instruments Inc., 部長
TAGUCHI Takao  Seiko Instruments Inc. Director, 部長
ENDO Kazutoyo  Tokyo Metoropolitan Univ. Fac. Of Sci. Associate Prof, 理学部, 助教授 (50106598)
KATADA Motomi  Tokyo Metoropolitan Univ. Fac. Of Sci. Associate Prof, 理学部, 助教授 (20094261)
Project Period (FY) 1988 – 1989
KeywordsCEMS / Surface layer / Scattering electron / Conversion electron Mossbauer spectroscopy / Characteristic X-ray / Mossbauer spectroscopy / Coincidence
Research Abstract

The X,gamma-ray coincidence system used in this study is shown in Fig. 1. The chemical state of ^<57>Fe atoms produced through the de-excitation associated with the nuclear transformation was studied by this system. The X,gamma-ray coincidence techniques were confirmed in various kinds of chemical compounds.
By means of the conventional conversion electron Mossbauer spectroscopy (CEMS), We also studied AMP surface layer of tin, tin- or zinc-coated iron plates corroded by various acids. Metastannic acid was formed, when the tin plate was corroded by nitric acid solution. In corrosion by phosphoric acid solution, tin(IV) pyrophasphate was formed. In corrosion of tin-coated iron plates maleic acid, malonic acid, formic acid, and oxalic acid were used. It was determined by CEMS that the corrosion products caused by these acids were tin(IV) oxides, although they could not by identified by the X-ray diffractometry. It was confirmed that CEMS was a useful technique for the studies on surface layers of corroded substance. Application of CEMS to iron-barium glaze was carried in order to clarify the chemical state of iron in the glaze.
The X-ray associated by irradiation of ^<57>Co-gamma-ray were determined by the use of solid state detector and the elements contained in tin- coasted iron were identified. In this experiment Mossbauer gamma-ray source (^<57>Co) was used as an irradiation source. Thus CEMS was combined with X-ray analysis.
However, Mossbauer spectroscopic microanalyzer was not confirmed sufficiently. We must be improve a colimating and spotting systems in future.

  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] Y.Watanabe: "Time-dependent Fe-^<57>-species in Co-57-labelled cobalt(II) iodate studied by means of coincidence Mossbauer spectroscopy" Hyperfine Int.42. 1025-1028 (1988)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Y.Watanabe: "X-Ray gatad Mossbauer spectrs ^<19>C studies on Co-^<57>-labelled cobalt(II) fluoride" J.Radiochem.Nucl.Chem Lett.136. 257-268 (1989)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 平島佳: "酸化鉄含有量と焼成零囲気による鉄-バリウムゆうの呈色変化" 日本化学会誌. 150-154 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Y. Watanabe: "Time-dependent Fe-57-species in Co-57 labeled cobalt(II) iodate studied by means of coincidence Mossbauer spectroscopy" Hyperfine Int., 42, 1025-1028 (1988).

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Y. Watanabe: "X-Ray gated Mossbauer spectroscopic studies on Co-57-labeled cobalt(II) fluoride" J. Radiochem. Nucl. Chem. Letters, 136, 257-266 (1989).

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Y. Hirashima: "Effect of firing atmosphere and iron concentration on color of iron-barium glaze" Nippon Kagaku Kaishi, (2), 150-154 (1990).

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1993-03-26  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi