Budget Amount *help |
¥39,520,000 (Direct Cost: ¥30,400,000、Indirect Cost: ¥9,120,000)
Fiscal Year 2012: ¥13,000,000 (Direct Cost: ¥10,000,000、Indirect Cost: ¥3,000,000)
Fiscal Year 2011: ¥12,870,000 (Direct Cost: ¥9,900,000、Indirect Cost: ¥2,970,000)
Fiscal Year 2010: ¥13,650,000 (Direct Cost: ¥10,500,000、Indirect Cost: ¥3,150,000)
|
Research Abstract |
In boron neutron capture therapy (BNCT) research, an examination of 10B distribution in tissue is very important. The a-autoradiography is useful as an imaging method for this purpose. We have developed a simple and rapid new method to precisely identify the position of 10B using the shape of etched pits such as a circularity. In this method, no special track detectors or special microscope is needed. By this new method, it is possible to identify a real position of 10B in um tissue specimen within 1.7um error.
|