• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to previous page

Development of the less invasive coronary artery imaging method for the high-risk patients group of the ischemic heart disase

Research Project

Project/Area Number 26461803
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeMulti-year Fund
Section一般
Research Field Radiation science
Research InstitutionIwate Medical University

Principal Investigator

YOSHIOKA Kunihiro  岩手医科大学, 医学部, 教授 (70210648)

Co-Investigator(Renkei-kenkyūsha) TANAKA Ryoichi  岩手医科大学, 医学部, 准教授 (30393218)
Research Collaborator MURANAKA Kenta  岩手医科大学, 附属病院, 副技師長
ARAKITA Kazumasa  東芝メディカルシステムズ, 研究開発センター
Project Period (FY) 2014-04-01 – 2017-03-31
Project Status Completed (Fiscal Year 2016)
Budget Amount *help
¥4,940,000 (Direct Cost: ¥3,800,000、Indirect Cost: ¥1,140,000)
Fiscal Year 2016: ¥780,000 (Direct Cost: ¥600,000、Indirect Cost: ¥180,000)
Fiscal Year 2015: ¥650,000 (Direct Cost: ¥500,000、Indirect Cost: ¥150,000)
Fiscal Year 2014: ¥3,510,000 (Direct Cost: ¥2,700,000、Indirect Cost: ¥810,000)
Keywords放射線 / 循環器 / 高血圧 / 臨床 / CT / 冠動脈 / 石灰化 / サブトラクション
Outline of Final Research Achievements

One of the major challenges in coronary computed tomography angiography (CCTA) is the presence of severe calcifications in the coronary arteries. We developed the subtraction coronary CCTA. Twenty patients with calcium scores of >400 underwent subtraction CCTA followed by invasive coronary angiography (ICA). The sensitivity, specificity, positive predictive value, and negative predictive value for subtraction CCTA were 94.1, 85.4, 82.1, and 95.3 %, respectively.
The conventional subtraction CCTA requires a long breath-holding time. This is a major problem in clinical practice. We explored a modified subtraction CCTA with a short breath-holding time. 11 patients with a calcium score >400 and short breath-holding time (<20 s) underwent modified subtraction CCT followed by ICA. The sensitivity, specificity, positive predictive value, and negative predictive value for subtraction CCTA were 90.9, 87.5, 76.9, and 95.5 %, respectively. The mean breath-holding time was 13.0 ± 0.9 s.

Report

(4 results)
  • 2016 Annual Research Report   Final Research Report ( PDF )
  • 2015 Research-status Report
  • 2014 Research-status Report
  • Research Products

    (17 results)

All 2016 2015 2014

All Journal Article (4 results) (of which Peer Reviewed: 4 results,  Acknowledgement Compliant: 4 results,  Open Access: 1 results) Presentation (10 results) (of which Invited: 6 results) Book (2 results) Patent(Industrial Property Rights) (1 results) (of which Overseas: 1 results)

  • [Journal Article] Diagnostic accuracy of a modified subtraction coronary CT angiography method with short breath-holding time: a fiesibility study2016

    • Author(s)
      Yoshioka K, Tanaka R, Takagi H, Nagata K, Chiba T, Takeda K, Ueda T, Sugawara T, Sasaki A, Ueyama Y, Kikuchi K, Sasaki T
    • Journal Title

      Br J Radiol

      Volume: 89 Issue: 1066 Pages: 20160489-20160489

    • DOI

      10.1259/bjr.20160489

    • Related Report
      2016 Annual Research Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] Modified subtraction coronary CT angiography method for patients unable to perform long breath-hold: a preliminary study2016

    • Author(s)
      Yoshioka K, Tanaka R, Nagata K, Sasaki T, Takeda K, Ueda T, SugawaraT, Ueyama Y, Chiba T, Sasaki A, Kikuchi K
    • Journal Title

      Acad Radiol

      Volume: 23 Issue: 9 Pages: 1170-1175

    • DOI

      10.1016/j.acra.2016.04.012

    • NAID

      120006349967

    • Related Report
      2016 Annual Research Report
    • Peer Reviewed / Open Access / Acknowledgement Compliant
  • [Journal Article] Subtraction coronary CT angiography using second-generation 320-detector row CT2015

    • Author(s)
      Yoshioka K, Tanaka R, Muranaka K, Sasaki T, Ueda T, Chiba T, Takeda K, Sugawara T
    • Journal Title

      Int J Cardiovasc Imaging

      Volume: 31 Suppl 1 Issue: S1 Pages: 51-58

    • DOI

      10.1007/s10554-015-0630-1

    • Related Report
      2015 Research-status Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Journal Article] hree-dimensional demonstration of the collateral circulation to the artery of Adamkiewicz via inferior epigastric artery with computed tomography angiography2015

    • Author(s)
      Yoshioka K, Tanaka R, Ueyama U, Abiko A
    • Journal Title

      Eur J Cardiothorac Surg

      Volume: 48 Issue: 1 Pages: 175-175

    • DOI

      10.1093/ejcts/ezu400

    • Related Report
      2015 Research-status Report
    • Peer Reviewed / Acknowledgement Compliant
  • [Presentation] 心臓CT2016

    • Author(s)
      吉岡 邦浩
    • Organizer
      第30回日本冠疾患学会
    • Place of Presentation
      杏林大学(三鷹市)
    • Year and Date
      2016-12-10
    • Related Report
      2016 Annual Research Report
    • Invited
  • [Presentation] 最新CTの臨床応用2016

    • Author(s)
      吉岡 邦浩
    • Organizer
      第45回日本断層映像研究会
    • Place of Presentation
      岡山市
    • Year and Date
      2016-10-21
    • Related Report
      2016 Annual Research Report
  • [Presentation] FFR-CTを使った新しい非侵襲的機能診断2016

    • Author(s)
      吉岡 邦浩
    • Organizer
      第75回日本医学放射線学会総会
    • Place of Presentation
      パシフィコ横浜(横浜市)
    • Year and Date
      2016-04-15
    • Related Report
      2016 Annual Research Report
  • [Presentation] 冠動脈サブトラクションとTAG(Transluminal Attenuation Gradient)解析2015

    • Author(s)
      吉岡邦浩
    • Organizer
      第51回日本医学放射線学会秋期臨床大会
    • Place of Presentation
      岩手県盛岡市
    • Year and Date
      2015-10-02
    • Related Report
      2015 Research-status Report
  • [Presentation] 冠動脈サブトラクションCTによる高度石灰化病変への対応:効能と限界2015

    • Author(s)
      吉岡邦浩
    • Organizer
      第63回日本心臓病学会学術集会
    • Place of Presentation
      パシフィコ横浜(横浜市)
    • Year and Date
      2015-09-20
    • Related Report
      2015 Research-status Report
    • Invited
  • [Presentation] 冠動脈サブトラクションにおけるミスレジストレーションの検討2015

    • Author(s)
      菅原毅、佐々木忠司、武田航太、永峰正幸、村中健太、吉岡邦浩
    • Organizer
      第71回日本放射線技術学会総会学術大会
    • Place of Presentation
      パシフィコ横浜(横浜市)
    • Year and Date
      2015-04-19
    • Related Report
      2015 Research-status Report
  • [Presentation] 冠動脈CTと高度石灰化をめぐる最近の話題:最新技術は本当につかえるか?2015

    • Author(s)
      吉岡邦浩
    • Organizer
      第19回東北心血管イメージング研究会
    • Place of Presentation
      仙台市
    • Year and Date
      2015-03-28
    • Related Report
      2014 Research-status Report
    • Invited
  • [Presentation] 動脈硬化性心疾患におけるチーム医療 放射線科の立場から2014

    • Author(s)
      吉岡邦浩
    • Organizer
      第28回日本臨床内科医学会
    • Place of Presentation
      盛岡市
    • Year and Date
      2014-10-12
    • Related Report
      2014 Research-status Report
    • Invited
  • [Presentation] 冠動脈サブトラクションの臨床応用2014

    • Author(s)
      吉岡邦浩
    • Organizer
      第50回日本医学放射線学会秋期臨床大会
    • Place of Presentation
      神戸市
    • Year and Date
      2014-09-26
    • Related Report
      2014 Research-status Report
    • Invited
  • [Presentation] 冠動脈CT最近の進歩:高度石灰化病変への対応2014

    • Author(s)
      吉岡邦浩
    • Organizer
      第104回日本循環器学会 中国・四国合同地方会
    • Place of Presentation
      岡山市
    • Year and Date
      2014-07-18
    • Related Report
      2014 Research-status Report
    • Invited
  • [Book] 循環器臨床を変えるMDCT2015

    • Author(s)
      吉岡邦浩
    • Total Pages
      313
    • Publisher
      文光堂
    • Related Report
      2015 Research-status Report
  • [Book] 別冊医学のあゆみ 循環器と画像診断Update2015

    • Author(s)
      吉岡邦浩,田中良一
    • Total Pages
      128
    • Publisher
      医歯薬出版株式会社
    • Related Report
      2014 Research-status Report
  • [Patent(Industrial Property Rights)] 特許権2015

    • Inventor(s)
      Sunami K、他5名(4番目)
    • Industrial Property Rights Holder
      Sunami K、他5名(4番目)
    • Industrial Property Rights Type
      特許
    • Filing Date
      2015-05-28
    • Acquisition Date
      2017-02-07
    • Related Report
      2016 Annual Research Report
    • Overseas

URL: 

Published: 2014-04-04   Modified: 2018-03-22  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi