2017 Fiscal Year Final Research Report
Optical detection of AC magnetic field by using alkali metal atoms
Project/Area Number |
16K18113
|
Research Category |
Grant-in-Aid for Young Scientists (B)
|
Allocation Type | Multi-year Fund |
Research Field |
Measurement engineering
|
Research Institution | Okayama University |
Principal Investigator |
Taue Shuji 岡山大学, 自然科学研究科, 助教 (80420503)
|
Project Period (FY) |
2016-04-01 – 2018-03-31
|
Keywords | 磁界分布 / 磁界計測 / 光学測定 |
Outline of Final Research Achievements |
We utilized an optical magnetometer to detect AC magnetic field. At first, small permanent magnets were used instead of big coils to generate static magnetic field around the sensor head. Non-uniform magnetic field from permanent magnets produced reduction of output signals and a higher bandwidth. Subsequently, we achieved to visualize magnetic field distributions with sub-millimeter resolutions by using a mirror array device. Uniform field distributions from Helmholtz coils and field decays from a fine wire were clearly obtained.
|
Free Research Field |
光計測
|